Laserfiche WebLink
LEGEND <br /> SITE DATA: <br />SEE STREET PLAN SHEETS C13 AND ~ <br /> PHASE 1 SITE "C" (NORTHWEST QUADRANT) <br />~ C14 FOR CITY STR ~ ' ~ ~ ~ HEAVY DUTY eRUMiNOUs EET PROFILE, PARCEL DATA: <br />/ SECTION UTILITES AND NOTES ~ • • • ~ • ~ • i ' ZONING: MX (MIXED USE) <br />',',i ° SW 40 <br />a.., b _ North Ilne of 1/ ' ° a'..aa ,a PROPOSED CONCRETE SURFACE F SW1 /4 of ~ BUILDING LASTING RELATIONSHIPS LOT AREA: 5.92 ACRES <br />a. 4 ° EXISTING DRIVEWAY <br />~ ~ I I <br />f~f~~~ff ~~ff~~ff~~f F--~- BUILDING DATA: <br />EXISTING DRIVEWAY SETBACKS (GUIDED BY NORTHWEST QUADRANT DESIGN GUIDELINES): <br />2 02 ~ F 0,~ I FRONT: 10~ 44' (15' SHOWN) RYAN COMPANIES US, INC. <br />SIDE : 1 5 50 South Tenth Street, Suite 300 <br />I REAR: N/A Minneapolis, MN 55403-2012 <br />~ <br />TRANSFORMER/ ENERATOR SEE SHEETS C13 AND C14 FOR ROAD IMPROVEMENTS G I TOTAL BUILDING AREA: 120,000 SF 612-492-4000 tel <br /> I TENANT AREA: 1 14,000 SF 612-492-3000 fax <br />ROPERTY UNE 7.0~: ; <br />15.4 10.0 , T G y. ~ R30.0 y . PARKING DATA: WWW.RYANCOMPANIES.coM <br /> SETBACKS: <br />18.0 . ~'?a;•'.M•- 48 DOCK 10 BULDI G A 32:8:...'. 1: ~,.i.q...../.. ' ' '.'~Q'(pJ:.. R18.D L CAU110NI MONITORING I R10~D 9 10' DR IN GE AN w~LLS. PROTECT W/ FRONT: N/A <br />48 DOCK : ~ : s' ; ~ ~ ORANGE SNOW FENCE <br /> SIDE: 15' NORTH <br />TRASH ROOM .'.''•::H~IVY' ONOLIS.':'''::''••.':''. :'''••:~'.~'R3: SIDE: 5' SOUTH PROJECT NAME <br />ELECTRICAL BOLLARD (3) REAR: 15' <br />ROOM i:. TO PROTECT SPRINKLER EXISTING WELL <br />ROOM 2 4 5 ADS .0 HE CITY CODE MINIMUM REQUIREMENTS: <br />I 1 SPACE/ 250 SF (4.0/1000) <br />1:' ; . 124 BASED ON NET FLOOR AREA <br /> TOTAL PARKING PROVIDED: <br /> A.) TOTAL STALLS PROPOSED: TRANSOMA <br />R3.0 R3.0 R3 0 3.0 453 STALLS = 3.78/1000 (BASED ON GROSS FLOOR AREA) <br />e . NORTHWEST <br />10 BUIU)ING SETBACK z D ?I w 10 DRAINAGE AN <br />~ UTILITY EASEMENT 15.0 ~ 4 RTY UNE ~ 24.0 ~ PROPS <br />I ; 0 24.0 TYP. S I T E NOTES : QUAD RANT <br />~ TYP. a. PROPERTY UNE 4 15.0 LOCATION <br />TO B/C ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE CITY <br />o OF NEW BRIGHTON SPECIFICATIONS AND BUILDING PERMIT REQUIREMENTS. NEW BRIGHTON, <br />~ R3.0 ~ . o , o R3.D z 3.0 o R3.0 REFER TO GRADING PLAN C7 FOR EXISTING AND PROPOSED GRADES. MINNESOTA <br />0 8.0 I ~ 2-STORY OFFICE ' <br />15' PARKING SETBACK REFER TO SHEETS C10-C12 FOR CIVIL CONSTRUCTION DETAILS. SHEET TITLE <br />120,000 SF 4 i o <br />FFE=904.5 ~ , ~ ~ ; 10 DRAINAGE AND ALL DIMENSIONS SHOWN ARE TO FACE OF CURB UNLESS NOTED SITE PLAN <br />3 UTY EASEMENT " SLAB ON GRADE uTl OTHERWISE. <br /> BUILDING DIMENSIONS REFER TO OUTSIDE OF BUILDING FACE (TYP.) <br />in I .0 R3.0 UNLESS OTHERWISE NOTED. <br />~ R3.0 R3.0 ~i mm <br />I o W ,.a 00 CONTRACTOR SHALL FIELD VERIFY THE LOCATIONS AND ELEVATIONS OF REVISIONS <br />i00 ~ 3 0~ EXISTING UTILITIES AND TOPOGRAPHIC FEATURES, SUCH AS EXISTING <br />'PT 1 +1<9.64€ SIGN: HANDICAPPED ' K ~ ~ GUTTER GRADES AT THE PROPOSED DRIVEWAYS, PRIOR TO THE START 07/31/07 -BID PACK#1 <br />i PARKING (4) R7-8a OF SITE GRADING. THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE 08/02/07 - RCWD SUBMITTAL ENGINEER OF ANY DISCREPANCIES OR VARIATIONS FROM THE PLANS. 08/03/07 -CITY SUBMITTAL. <br />3 mo <br />: ~ R3.0 ;;g~ ~ R3.0 ~ ~ HANDICAPPED PARKING STALLS WILL BE PROVIDED AND IDENTIFIED PER 08/09/07 -MDH SUBMITTAL <br /> ADA CODES AND LOCATED ON SITE PLAN FOR CONSTRUCTION. ns/13/07 - RCWD COMMENT <br />{ DICAP RAMP -.•o R3.0 GUARD RAIL t a 3.0 CITY COMMENT ALL CURB AND GUTTER TO BE CONCRETE B612 ON PRIVATE PROPERTY 08/15/07 -MDH PLUMBING SUBMITTAL <br />MnDOT SPEC 68307 UNLESS NOTED OTHERWISE, 8618 CONCRETE CURB AND GUTTER ON os/24/o7 -BUILDING PERMIT suBMITTAL <br />~ R100. a ~ 2 PAT10 PUBLIC STREETS <br />~ R124.0 ALL FACE OF CURB RADII WILL BE 5.0' UNLESS NOTED OTHERWISE. <br />SIGN: HANDICAPPED PARKING de VAN ACCESS <br />7-Ba do 2 R7-8b ~ R3.0 R3.0 (2) R O a`l ~o TYPICAL FULL SIZE 90' PARKING STALL IS 9'X18' UNLESS NOTED <br />9 OTHERWISE. <br />1 'io0 LIGHT STANDARDS TO BE ON 36" BASE ABOVE PAVEMENT (TYP.) REFER <br />~ SIGN: HANDICAPPED ~ TO LIGHTING PLAN FOR FOOTCANDLE PRINT OUT. <br />PARKING 4 R7-8a ~ R .0 ° RETAINING <br />°'h WALL <br />4 STRIPING & S I G N AG E NOTES : I hereby certify that this plan, specification, <br />15 R3.0 or report was prepared by me or under my <br />15.7 R30 00 ALL PARKING STALL STRIPING TO BE 4"-WIDE WHITE PAINT direct supervision and that I am a duly <br />4 • Licensed Professional Engineer under the <br /> • HANDICAPPED STALLS AND ACCESS AISLES TO BE WHITE PAINT laws of the State of Minnesota. <br />m PER ADA STANDARDS <br />TEMPORARY R .0 CUL-DE-SAC R .0 m~ <br />00 ` R3.0 • ALL SIGNS TO BE MOUNTED ON 10' GREEN ENAMEL CHANNEL SIGN <br /> POSTS (REFER TO PLAN FOR SIGNAGE) <br />/ ~ 5 R3.0 R34.0 <br />' R3.0 WAR N I N G DANIEL E. BOWAR <br />52.6 ~ R3.0 5 THE CONTRACTOR SHALL CONTACT ALL PUBLIC <br />12 3 10 BUILDING SETBACK ~ NO DRAINAGE AND UTILITY R10. UTILITIES FOR LOCATIONS OF ALL UNDERGROUND <br />~ EASEMENT ALONG SOUTH ~ ROPERTY UNE R25.0 R3.0 WIRES, CABLES, CONDUITS, PIPES, MANHOLES, <br />R3.0 .aoTOT VALVES, OR OTHER BURIED STRUCTURES BEFORE <br />~ i ~ 888,00 ,:.:.L 5 PARKING SETBACK _ 5 T P s.ooTOP DIGGING. HE SHALL REPAIR OR REPLACE THE REGISTRATION NO. DATE ABOVE WHEN DAMAGED DURING CONSTRUCTION AT 45018 08 / 24 ~ 2007 <br />aso.zogoT OB T ~ 4.50 TOP NO COST TO OWNER. <br />893.00 B0T ~ _ 28.9 .30 TOP <br />_ ~ 894.50 gOT ; ~ PROP © 2006 RYAN COMPANIES US, INC. ;..gyp <br />PROPERTY UNE RETAINING WALL .I 896.00 BO ? <br />GUARD RAIL MnDOT SPEC 88307 <br />\ ~ ~''ff~11 JOB NUMBER HISTORY <br />\ _ ~.Y~ <br />~ ~ <br />~ ~ ~ ~ ~ <br />~ ~ ~ ~ ~ ~ ~ ~ 651-454-0002 <br />~ ~ uJ ~ ~ <br />\ ~ ~ \ ~ ~ ~ ~ ~ 800-252-1166 <br />~ ~ ~ ~ ~ ~ ~ ~ ~ Ryan lD# 7470 <br />~ ~ ~ <br />~ ~ ~ ~ ~ ~ ~ ~ ~ <br />~ ~ ~ ~ ~ ~ ~ . ~ SHEET NUMBER <br />~ ~ . <br />W I~ ~a3ae a~~t~3£ <br />~ f f ~ t#i <br />' DRAWN BY CHECKED BY <br />L REGIONAL POND O 40 DEB WTS <br />N WL= 878, 5 JOB NUMBER DATE <br />HWL=881.2 EOF=882.0 ~i SCALE IN FEE? 1735-000 08 ~ 24 i 2007 <br />I ~ , i i <br />