/ GENERAL CONSTRUCTION NOTES \ rri <br /> STRUCTURAL NOTES all n a Mobile• <br /> 1. THE FACILITY IS AN UNOCCUPIED WIRELESS FACILITY. 1.0 GENERAL CONDITIONS <br /> 2. PLANS ARE NOT TO BE SCALED AND ARE INTENDED TO BE A DIAGRAMMATIC 1.1 DESIGN AND CONSTRUCTION OF ALL WORK SHALL CONFORM TO <br /> OUTLINE ONLY, UNLESS NOTED OTHERWISE. THE WORK SHALL INCLUDE THE APPROVED EDITION OF THE IBC EDITION AND ALL OTHER CROWN <br /> FURNISHING MATERIALS, EQUIPMENT, APPURTENANCES AND LABOR NECESSARY APPLICABLE STATE CODES, ORDINANCES, AND REGULATIONS. IN CASE CASTLE <br /> TO COMPLETE ALL INSTALLATIONS AS INDICATED ON THE DRAWINGS. OF CONFLICT BETWEEN THE CODES, STANDARDS, AND REGULATIONS. `� <br /> SPECIFICATIONS, GENERAL NOTES AND/OR MANUFACTURER'S / ROJECT INFORMATION: <br /> 3. PRIOR TO THE SUBMISSION OF BIDS, THE CONTRACTORS SHALL VISIT THE REQUIREMENTS. USE THE MOST STRINGENT PROVISION. <br /> JOB SITE AND BE RESPONSIBLE FOR ALL CONTRACT DOCUMENTS, FIELD Al N0924G <br /> CONDITIONS AND DIMENSIONS, AND CONFIRMING THAT THE WORK MAY BE 1.2 IT IS THE EXPRESS INTENT OF THE PARTIES INVOLVED IN THIS <br /> ACCOMPLISHED AS SHOWN PRIOR TO PROCEEDING WITH CONSTRUCTION. ANY PROJECT THAT THE CONTRACTOR OR SUBCONTRACTOR OR WOLKENSTORFER <br /> DISCREPANCIES ARE TO BE BROUGHT TO THE ATTENTION OF THE INDEPENDENT CONTRACTOR OR THEIR RESPECTIVE EMPLOYEES SHALL <br /> IMPLEMENTATION ENGINEER AND ARCHITECT/ENGINEER PRIOR TO PROCEEDING EXCULPATE THE ARCHITECT, THE ENGINEER, THE CONSTRUCTION CCI SITE 829143 <br /> WITH THE WORK. MANAGER, THE OWNER, AND THEIR AGENTS, FROM ANY LIABILITY <br /> WHATSOEVER AND HOLD THEM HARMLESS AGAINST LOSS, DAMAGES. 348 1ST ST. SW <br /> 4. THE CONTRACTOR SHALL RECEIVE, IN WRITING, AUTHORIZATION TO PROCEED LIABILITY OR ANY EXPENSE ARISING IN ANY MATTER FROM THE NEW BRIGHTON, MN, 55112 <br /> BEFORE STARTING WORK ON ANY ITEM NOT CLEARLY DEFINED OR IDENTIFIED WRONGFUL OR NEGLIGENT ACT, OR FAILURE TO CARRY OUT THE `ISSUED FOR: <br /> BY THE CONTRACT DOCUMENTS. WORK IN ACCORDANCE WITH THE CONTRACT DOCUMENTS, OR THE <br /> CONSTRUCTION NS, OR <br /> 5. CONTRACTOR SHALL CONTACT LOCAL DIGGERS HOTLINE 48 HOURS PRIOR <br /> PROCEDURES TO CONFORMHODS, NES TOUTHESEQUENCES SATE SCAFFOLDING CONSTRUCTION <br /> TO PROCEEDING WITH ANY EXCAVATION, SITE WORK OR CONSTRUCTION. ACT IN CONNECTION WITH THE WORK. <br /> EV.:=DATE: DESCRIPTION: • <br /> 6. THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS IN 1.3 DO NOT SCALE DRAWINGS. <br /> ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS UNLESS SPECIFICALLY 8/05/14 PREUM CONST OL <br /> INDICATED OTHERWISE OR WHERE LOCAL CODES OR REGULATIONS TAKE 1.4 VERIFY ALL EQUIPMENT MOUNTING DIMENSIONS PER ® 9/2/14 CONSTRUCTION JN <br /> PRECEDENCE. MANUFACTURER DRAWINGS. <br /> 7. ALL WORK PERFORMED AND MATERIALS INSTALLED SHALL BE IN STRICT 1.5 SUBMIT ONE SEPIA AND TWO PRINTS OF ALL STRUCTURAL SHOP <br /> ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS AND ORDINANCES. DRAWINGS. MARKED UP SEPIA SHALL BE RETURNED. A <br /> CONTRACTOR SHALL GIVE ALL NOTICES AND COMPLY WITH ALL LAWS, Q <br /> ORDINANCES, RULES, REGULATIONS AND LAWFUL ORDERS OF ANY PUBLIC 1.6 DESIGN LOADS ARE: <br /> AUTHORITY REGARDING THE PERFORMANCE OF THE WORK. MECHANICAL AND WIND SPEED 90 MPH 3 SEC EXP C Q <br /> ELECTRICAL SYSTEMS SHALL BE INSTALLED IN ACCORDANCE WITH ALL SNOW LOAD 42 PSF <br /> APPLICABLE MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS, AND LOCAL AND A <br /> STATE JURISDICTIONAL CODES, ORDINANCES AND APPUCABLE REGULATIONS. 2.0 STEEL <br /> A <br /> 8. THE GENERAL CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK, 2.1 MEET OR EXCEED THE FOLLOWING CODES & STANDARDS <br /> USING THE BEST SKILLS AND ATTENTION. THE CONTRACTOR SHALL BE SOLELY (LATEST EDITION) EXCEPT AS NOTED: A <br /> RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, TECHNIQUES, <br /> SEQUENCES AND PROCEDURES AND FOR COORDINATING ALL PORTIONS OF THE A. STRUCTURAL STEEL...AISC SPECIFICATION & CODE OF STANDARD LANS PREPARED BY: 1 <br /> WORK UNDER THE CONTRACT INCLUDING CONTACT AND COORDINATION WITH PRACTICE <br /> THE CONSTRUCTION FIELD ENGINEER AND WITH THE LANDLORD'S AUTHORIZED -SHAPES AND PLATES...ASTM A572 *CENTERLINE <br /> REPRESENTATIVE. -PLATES BENT OR COLD FORMED..ASTM A 283, GRADE C t. <br /> 9. DETAILS ARE INTENDED TO SHOW END RESULT OF DESIGN. MINOR -S-STRUUCTCTURURAALL A 53, GRADE B <br /> SHEETS, HOT ROLLED..ASTM A 510 Advancing lOelessNetworks <br /> MODIFICATIONS MAY BE REQUIRED TO SUIT JOB DIMENSIONS OR CONDITIONS, -COLD FORMED STEEL TUBING...ASTM A 500 GRADE B <br /> 16360 TABLE MOUNTAIN PARKWAY <br /> AND SUCH MODIFICATIONS SHALL BE INCLUDED AS PART OF THE WORK. -BOLTS, NUTS & WASHERS FOR ANCHOR BOLTS AND SECONDARY GOLDEN.CO 80403 <br /> CONNECTIONS...ASTM A307 303-993-3293 <br /> 10. REPRESENTATIONS OF TRUE NORTH, OTHER THAN THOSE FOUND ON THE -ALL STEEL SHALL BE HOT-DIPPED GALVANIZED. WWWCENTERLINESOWTIONS.COM <br /> PLOT OF SURVEY DRAWING, SHALL NOT BE USED TO IDENTIFY OR ESTABLISH <br /> THE BEARING OF TRUE NORTH AT THE SITE. THE CONTRACTOR SHALL RELY B. WELDS...AWS E 70XX \ _J <br /> RAWN BY:-CHK.:= .. <br /> SOLELY ON THE PLOT OF SURVEY DRAWING AND ANY SURVEYOR'S MARKINGS EXCEPTION IS TAKEN TO AISC CODE OF STANDARD PRACTICE EX IJN 1 -D <br /> KS <br /> AT THE SITE FOR THE ESTABLISHMENT OF TRUE NORTH, AND SHALL NOTIFY PARAGRAPH 4.2.1 REGARDING OWNERS AND FABRICATOR'S <br /> THE ARCHITECT/ENGINEER PRIOR TO PROCEEDING WITH THE WORK IF ANY RESPONSIBILITY FOR CONNECTION DESIGN AND DETAILING IS THE CENSURE: <br /> DISCREPANCY IS FOUND BETWEEN THE VARIOUS ELEMENTS OF THE WORKING CONTRACTORS RESPONSIBILITY. ENGINEER'S REVIEW OF SHOP 1 <br /> DRAWINGS AND THE TRUE NORTH ORIENTATION AS DEPICTED ON THE PLAT OF DRAWINGS IS FOR GENERAL CONSIDERATIONS ONLY AND DOES NOT <br /> SURVEY. THE CONTRACTOR SHALL ASSUME SOLE LIABILITY FOR ANY FAILURE TO CONSTITUTE AN ACCEPTANCE OF THESE RESPONSIBILITIES BY THE <br /> NOTIFY THE ARCHITECT/ENGINEER. OWNER AND/OR ENGINEER. <br /> 3.0 STANDARDS FOR ALL CONCRETE WORK H�RQ- <br /> Certify that this plan,specification, or <br /> 3.1 ALL CONCRETE WORK SHALL CONFORM WITH ACI. 318 OR report rN Is prepared by me or under my direct <br /> LATEST. DETAIL REINFORCING IN CONFORMANCE WITH ACI. SP66 supers:S On and that I am a duly Licensed <br /> LATEST. P:nfevai anal Engineer under the laws of the <br /> 3.2 NO SPLICES OF REINFORCEMENT SHALL BE MADE EXCEPT AS State of Mini Icsota. <br /> DETAILED OR AUTHORIZED BY THE STRUCTURAL ENGINEER. LAP Khristopher�mes SA <br /> t SPLICES WHERE PERMITTED SHALL BE A MINIMUM OF 30 BAR Print None• p <br /> DIAMETERS. <br /> 3.3 PROVIDE ALL ACCESSORIES NECESSARY TO SUPPORT SigI1 tt rcll <br /> REINFORCING AT POSITIONS SHOW ON DRAWINGS. DaleSCpp ) 111/ License# 50231 ; <br /> 3.4 WIRE FABRIC REINFORCEMENT MUST LAP ONE FULL MESH AT <br /> SIDE AND END LAPS SHALL BE TIED TOGETHER. <br /> 3.5 CURE AFTER FINISHING CONCRETE. KEEP MOIST FOR 7 DAYS GENERAL <br /> AFTER POURING. NOTES <br /> 3.6 COMPACT STRUCTURAL FILL 95% PROCTOR DENSITY PRIOR TO <br /> PLACING CONCRETE UNDER SLABS. <br /> 3.7 1/4" CHAMFER ON ALL CORNERS AND EDGES. <br /> ,SCALES SET FOR A 245e36' "D"SIZE SHEET J <br /> 3.8 ALL CONCRETE SHALL BE PORTLAND, TYPE 1 CEMENT WITH A 'SHEET NUMBER: <br /> MINIMUM OF 28 DAY STRENGTH OF 3000 PSI.. 4" SLUMP AND A <br /> MINIMUM AIR ENTRAPMENT OF 4%. <br /> 3.9 ALL REINFORCING STEEL SHALL BE GRADE 60. ALL REINFORCING <br /> G N "I <br /> MESH SHALL CONFORM TO ASTM A 185. <br />