My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2016.05.17 Planning Commission Packet Combined
NewBrighton
>
Commissions
>
Planning
>
Planning Commission Packets
>
2016
>
2016.05.17 Planning Commission Packet Combined
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/11/2017 11:21:09 AM
Creation date
1/11/2017 10:33:48 AM
Metadata
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
79
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 1'-4" 2'-8" 5'-4"2JOIST LAYOUTSHEAR WALLS AND END WALLS:NAILING SCHEDULE:1. 8d NAILS 6" O.C. ALL PANEL EDGES.2. REMAINING NAILS 12" O.C.3.716" A.P.A. RATED SHEATHING (BOTH SIDES OF WALLS)0 1'-4" 2'-8" 5'-4"1FLOOR PLANNOTE:WALL WITH WINDOWS TO BE 2x6'S - 16" O.C.REMAINING (3) WALLS TO BE 2x4'S - 16" O.C.NOTE:1. ELECTRICAL CONDUIT AND WIRING TO BE BURIED IN STRUCTURE.2. ELECTRICAL OUTLETS - INSTALL SINGLE DUPLEX OUTLETS IN EACH COMPARTMENT FORELECTRIC HEATER.3. LIGHT FIXTURES - 24" x 48", 3 LAMP STATIC FLUORESCENT RECESSED LAY-IN GRIDTROFFER FLUSH STEEL DOOR FRAME. 1/2" x 1/2" x 1/2" SILVER PLASTIC CUBELOUVER.4. PROVIDE SURFACE MOUNTED, HIGH ABUSE INCANDESCENT FIXTURE WITH POLYCARBONATE GLOBE AT EACH ENTRANCE.5. WIRING TO MEET REQUIRED SERVICE CONDUIT TO BE STUBBED OUT OF PRESS BOXREADY FOR RE-CONNECT6. LOCATE MAIN DISCONNECT AND CIRCUIT BREAKER ON SHOP DRAWINGS.7. RECONNECT EXISTING WIRING FOR SCOREBOARD CONTROLS, P.A. SYSTEM, ANDCOACHES COMMUNICATION EQUIPMENT, INCLUDE THE PULLING OF WIRE TO THECOMMUNICATION BOXES AND PROVIDE REQUIRED CONNECTORS.8. PROVIDE SURFACE METAL RACEWAY MOUNTED ABOVE COUNTERTOP, BUT BELOWWINDOW, TWO-PIECE CONTINUOUS WALL TO WALL, SINGLE RECEPTACLES 18" ONCENTER.9. PRESSBOX SUPPLIER TO FURNISH AND INSTALL TWO WATERPROOF , G.F.C.I. DUPLEXRECEPTACLES WITH "IN-USE" COVERS, ON ROOF. MOUNT ON HANDRAIL, ON ROOF,18" ABOVE ROOF DECK CONCEAL IN STRUCTURE AND STUB OUT OF STRUCTURE ATRECEPTACLE.10. PROVIDE 2-GANG JUNCTION BOX WITH 1/2" CONDUIT TO COMMUNICATIONS CABINETAT EACH WALL, ADJACENT TO COUNTERTOP AND PROVIDE FOR WEATHERPROOFJUNCTION BOXES DIRECTLY ADJACENT TO ELECTRICAL ON ROOF.ELECTRICAL NOTES:PRE-FABRICATED PRESS BOX SHALL COME WITH A COMPLETETLY FINISHEDELECTRICAL SYSTEM. EMPTY CONDUITS FOR SPEAKER WIRES, SCOREBOARDCONTROLS, AND OTHER RELATED FUNCTIONS SHALL BE STUBBED TO OUTSIDE OFPRESS BOX FOR HOOK-UP BY ELECTRICAL CONTRACTOR.DATA AND PHONEFIELD COMMUNICATIONSCOREBOARD CONTROLPUBLIC ADDRESS CONTROL100 AMP PANEL, LOCATED ON REAR WALL.DUPLEX OUTLETS ALONG REAR WALL, ONE PER 6' OF BOX.LOW VOLTAGE PANEL, LOCATED ON REAR WALL.CONTINUOUS PLUG MOLD 2000 ALONG TOTAL LENGTH OF FRONT WALLRECEPTACLES AT 2'-0" O.C. PLUG MOLD AT 32" ABOVE FLOOR. (ABOVE INTERIORSHELF AND BELOW WINDOW SILL)ABCDE1234(RIM JOIST TO RIM JOIST DIMENSION)TRIPLE 2x8 RIM JOISTS2x8 JOISTS 12" o.c.#2 AND BETTER S.P.F.(RIM JOIST TO RIM JOIST DIMENSION)J.SITELINE GLIDING WINDOWR.O. 5'-0" x 4'-0"4" OVERHANG(TYPICAL)SHEATHING TO SHEATHING DIMENSIONSHEATHING TO SHEATHING DIMENSION12ELIGHT FIXTURE(TYP.)333322221111111112'-0"12'-0"RADIOHOME COACHP.A./CLOCK/SCORERSPOTTER/VIDEOCABLEVISITING COACHRADIOINSTALL 10 - 112"∅GROMMETS18" COUNTER-TOP 18" COUNTER-TOP 18" COUNTER-TOP 18" COUNTER-TOP 18" COUNTER-TOPEEE12343'-334"5'-614"6'-4"6'-312"5'-6"5'-6"6'-312"6'-4"5'-614"3'-334"53'-11"4'-4"9'-1"3'-0"1'-10" x 3'-6" PLATE GLASSTEMPERED (TYP.)SHEAR WALLSHEAR WALL4'-4"9'-1"SHEATHING TO SHEATHING DIMENSIONDBCFCC12'-0"6'-4"4'-078"13'-218"53'-11"SHEATHING TO SHEATHING DIMENSIONCUP 9 RISERSTO ROOF2'-6"3'-9"9'-3"OPENING FOR 3'-0" x 8'-0" ROOF HATCH2'-11"6'-0"6'-0"6'-0"6'-0"6'-0"6'-0"6'-0"6'-0"2'-11"53'-10"9'-0"(RIM JOIST TO RIM JOIST DIMENSION)9'-0"11'-1112"29'-11"11'-1112"53'-10"(RIM JOIST TO RIM JOIST DIMENSION)DOUBLE 2x8 JOISTSAT EACH ENDSHEAR WALLSHEAR WALL2x6 BEARING PLATES6'-0" O.C. WITH A2x8 JOIST ABOVEQUAD 2x8 CEILING JOISTSAND 2x8 FLOOR JOISTS ATINTERIOR SHEAR WALLS2'-6"J.SITELINESTATIONARY WINDOWR.O. 1'-8" x 4'-0"J.SITELINESTATIONARY WINDOWR.O. 1'-8" x 4'-0"2'-6"3J.SITELINE GLIDING WINDOWR.O. 5'-0" x 4'-0"J.SITELINE GLIDING WINDOWR.O. 5'-0" x 4'-0"J.SITELINE GLIDING WINDOWR.O. 5'-0" x 4'-0"J.SITELINE GLIDING WINDOWR.O. 5'-0" x 4'-0"J.SITELINE GLIDING WINDOWR.O. 5'-0" x 4'-0"J.SITELINE GLIDING WINDOWR.O. 5'-0" x 4'-0"J.SITELINE GLIDING WINDOWR.O. 5'-0" x 4'-0"J.SITELINE GLIDING WINDOWR.O. 5'-0" x 4'-0"1212123C12'-0"6'-4"3'-0"3'-0"2'-3"2'-3"3'-0"CC2'-8"KEYNOTES1. SIMPSON MSTC48 HOLD-DOWN LOCATION. PLACE UNDER JOIST AND NAIL TO DOUBLESTUD PER MANUFACTURER RECOMMENDATIONS.2. HUC 28-2 HANGER EACH END DOUBLE JOIST TO RIM UNDER ENDWALL.THE DESIGNS AND PLANS INDICATED ON THISDRAWING, ARE THE PROPERTY OF PRO-BUILD,OSAKIS, MN. ALL RIGHTS ARE RESERVED. NODESIGNS OR PLANS WILL BE USED ORREPRODUCED IN ANY FORM OR BY ANY MEANSWITHOUT WRITTEN PERMISSION OF PRO-BUILD,OSAKIS, MN.AUTHORIZED BY:I HEREBY CERTIFY THAT THIS PLAN, SPECIFICATION,OR REPORT WAS PREPARED BY ME OR UNDER MYDIRECT SUPERVISION AND THAT I AM A DULYLICENSED PROFESSIONAL ENGINEER UNDER THELAWS OF THE STATE OF MINNESOTA.DATE:LICENSE #:PRINTED NAME: JOE A. NICHOLSON441044/20/16
The URL can be used to link to this page
Your browser does not support the video tag.