ELECTRICAL DRAWINGSELECTRICAL ABBREVIATIONS LISTC CONDUITCATV CABLE TELEVISIONCB CIRCUIT BREAKER CCTV CLOSED CIRCUIT TELEVISIONCKT CIRCUITCLG CEILINGCMPR COMPRESSORCONN CONNECTIONCONT CONTINUATION OR CONTINUOUSCONTR CONTRACTORCONV CONVECTORCP CIRCULATING PUMPCT CURRENT TRANSFORMERCTR CENTERCU COPPERDCP DOMESTIC WATER CIRCULATING PUMPEX EXISTING TO REMAINHTR HEATERHV HIGH VOLTAGEHWP HYDRONIC WATER PUMPIC INTERRUPTING CAPACITYIG ISOLATED GROUNDIMC INTERMEDIATE METAL CONDUITINCAND INCANDESCENTIR INFRAREDI/W INTERLOCK WITHJ-BOX JUNCTION BOXKV KILOVOLTKVA KILOVOLT-AMPEREKVAR KILOVOLT-AMPERE REACTIVEKW KILOWATTKWH KILOWATT HOURLOC LOCATE OR LOCATIONLT LIGHTLTG LIGHTINGLTNG LIGHTNINGLV LOW VOLTAGEMAG.S MAGNETIC STARTERM/C MOMENTARY CONTACTMCB MAIN CIRCUIT BREAKERMCC MOTOR CONTROL CENTERMDC MAIN DISTRIBUTION CENTERMDP MAIN DISTRIBUTION PANELMFR MANUFACTURERMFS MAIN FUSED DISCONNECT SWITCHMLO MAIN LUGS ONLYMMS MANUAL MOTOR STARTERMOA MULTIOUTLET ASSEMBLYMSP MOTOR STARTER PANELBOARDMSBD MAIN SWITCHBOARDMT MOUNTMT.C EMPTY CONDUITMTS MANUAL TRANSFER SWITCHMTR MOTOR, MOTORIZEDUE UNDERGROUND ELECTRICALUG UNDERGROUNDUH UNIT HEATERUT UNDERGROUND TELEPHONEUV UNIT VENTILATOR OR ULTRAVIOLETV VOLTVA VOLT-AMPERESVERT VERTICALVFD VARIABLE FREQUENCY DRIVEVOL VOLUMEW WATTW/ WITHWG WIRE GUARDWH WATER HEATERW/O WITHOUTWP WEATHERPROOFXFMR TRANSFORMERXFR TRANSFERRCPT RECEPTACLEREQD REQUIREDRL RELOCATEDRSC RIGID STEEL CONDUITRTU ROOF TOP UNITSC SURFACE CONDUITSEC SECONDARYSHT SHEETSIM SIMILARS/N SOLID NEUTRALSPKR SPEAKERSP SPARESR SURFACE RACEWAYSS STAINLESS STEELSSW SELECTOR SWITCHS/S STOP/START PUSHBUTTONSSTA STATIONSTD STANDARDSURF SURFACE MOUNTEDSW SWITCHSWBD SWITCHBOARDSYM SYMMETRICALTERM TERMINALTL TWIST LOCKTR TAMPER RESISTANTT-STAT THERMOSTATTTC TELEPHONE TERMINAL CABINETTVTC TELEVISION TERMINAL CABINETTYP TYPICALN.C. NORMALLY CLOSEDNEC NATIONAL ELECTRICAL CODENEMA NATIONAL ELECTRICAL MANUFACTURER'S ASSOCIATIONNFDS NON-FUSED SAFETY DISCONNECT SWITCHNIC NOT IN CONTRACTNL NEW LOCATIONN.O. NORMALLY OPENNPF NORMAL POWER FACTORNTS NOT TO SCALEOH OVERHEADOL OVERLOADSPA PUBLIC ADDRESSPB PULL BOXPE PNEUMATIC ELECTRICPED PEDESTAL PF POWER FACTORPH PHASEPNL PANELPP POWER POLEPR PAIRPRI PRIMARYPROJ PROJECTIONPRV POWER ROOF VENTILATORPT POTENTIAL TRANSFORMERPVC POLYVINYL CHLORIDE (CONDUIT)PWR POWERQUAN QUANTITY< ANGLE@ AT' FEET" INCHES# NUMBER1P 1 POLE (2P, 3P, 4P, ETC.)A AMPEREAC AIR CONDITIONERACLG ABOVE CEILINGADO AUTOMATIC DOOR OPENERAFF ABOVE FINISHED FLOORAFG ABOVE FINISHED GRADEAFI ARC FAULT CIRCUIT INTERRUPTERAHU AIR HANDLING UNITAL ALUMINUMALT ALTERNATEAMP AMPLIFIERANNUN ANNUNCIATORAQ-STAT AQUASTATATS AUTOMATIC TRANSFER SWITCHAV AUDIO VISUALAWG AMERICAN WIRE GAUGEBATT BATTERYBD BOARD BLDG BUILDINGBAS BUILDING AUTOMATION SYSTEM DEVICE ABBREVIATIONS:C. WASH CLOTHES WASHERC. DRY CLOTHES DRYERDISH DISHWASHERDISP UNDER SINK DISPOSERFLSH SANITARY AUTOMATIC FLUSHGOGG GOGGLES CABINET HAND HAND DRYERHOOD EXHAUST HOODMWV MICROWAVE OVN ELECTRIC OVEN##PC PCOS#LLIGHTINGPOWER DISTRIBUTION AND EQUIPMENTLIGHTING CONTROLGENERAL ELECTRICAL SYMBOLSBRANCH CIRCUIT, FEEDER, RACEWAY& FURNITURE CONNECTIONSPOKE-THRU'S, FLOOR BOXES,FIRE ALARM DEVICESPOWER AND MOTOR DEVICESCOMMUNICATION DEVICESSECURITY DEVICESFCSFF/SFTSFFLFIFCMFZFGSFRSDFFH136°HFDPTPRSLASMCSKPSEESDRSCRS##FCEILING OR WALL MOUNTED JUNCTION BOX WITH REQUIRED COVERPLATE - PLAN INDICATES FUNCTIONMSPMSSMSDISCONNECT SWITCH - NON FUSED.MOTOR RATED SWITCH AND PILOT.MOTOR STARTER SWITCH WITH MOTOR RUNNING PROTECTION (ADD RELAY IF CONTROL CONTACTS ARE REQUIRED).MOTOR RATED SWITCH.PUSHBUTTON - WALL MOUNTED.RELAY - VERIFY MOUNTING HEIGHT; SEE DRAWINGS.MOTOR, SEE MOTOR AND EQUIPMENT SCHEDULECOMBINATION STARTER/DISCONNECT SWITCH.LINEAR PENDANT LIGHTING FIXTURE; FOR SUSPENDED MOUNTING HEIGHTS, SEE DRAWINGS.TRACK LIGHTING FIXTURE (WITH HEADS OR PENDANTS); LENGTH AND MOUNTING AS NOTED ON DRAWINGS.EXIT LIGHT-FACE SHOWN SHADED; PLAN INDICATES CEILING OR WALL MOUNTING AND DIRECTIONAL ARROWS.ATSWALL MOUNTED LIGHTING FIXTURE; SEE REFLECTED CEILING PLAN FOR MOUNTING HEIGHT.TRANSFORMER, WITH SIZE AS NOTED. SEE RISER DIAGRAM, SCHEDULE OR FLOOR PLANS; VERIFY.PULLBOXMOTOR CONTROL CENTER (W/CONCRETE PAD); FLOOR MOUNTED.PLUG-IN BUS DUCT SWITCH; SIZE AS INDICATED AND SPECIFIED. VERIFY MOUNTING HEIGHT.METER/SOCKET ASSEMBLY; MOUNT TOP AT 6'-0".MPBMCCTSWITCHBOARD WITH CONCRETE PAD:FLOOR MOUNTED.PANELBOARD; WALL MOUNTED WITH TOP 6'-0".RELAY/CONNECTION CABINET;WALL MOUNTED, WITH TOP 6'-0".AUTOMATIC TRANSFER SWITCH;WALL OR FLOOR MOUNTED.SYMBOLDESCRIPTIONELECTRICAL SYMBOL SCHEDULESYMBOLDESCRIPTIONCIRCULAR PENDANT LIGHT FIXTURE; FOR SUSPENDED MOUNTING HEIGHTS, SEE DRAWINGS.POLE MOUNTED SITE LIGHTING FIXTURE - SINGLE SQUARE HEAD. # OF HEADS AS SHOWN.EACH SYMBOL DENOTES A SINGLE POLE LIGHT SWITCHWHEN MULITPLE SWITCHES ARE SHOWN, LOCATE ALL UNDER SINGLE MULTI-SWITCH COVERPLATE.INDICATES CONDUIT IS SURFACE MOUNTEDINDICATES CONDUIT ROUTED BELOW OR IN FLOOR STRUCTURE OR BELOW GRADE OR AS NOTED.INDICATES CONDUIT ROUTED CONCEALED ABOVE FLOOR OR GRADE (IN CEILING OR WALL)SURFACE RACEWAY ASSEMBLY. PROVIDE AS SPECIFIED, UNLESS NOTED OTHERWISE.INDICATES 1" CONDUIT, (3) NO. 4 AWG CONDUCTORS AND (1) NO. 3 GROUND WIRECONDUIT STUB - TERMINATION INDICATED BY NOTECABLE TRAY (WIDTH X DEPTH)1"C,3#4+1#3GINDICATES CONDUIT UPINDICATES CONDUIT DOWNDESCRIPTIONPOKE-THROUGH (PT) OR FLOOR BOX (FB), FULLY RECESSED IN FLOOR. REFER TO POKE-THROUGH AND FLOOR BOX SCHEDULE.DESCRIPTIONSPECIAL PURPOSE OUTLET; WALL OR RECESSED CEILING MOUNTEDRECESSED CEILING MOUNTED SINGLE OR DUPLEX RECEPTACLE W/ ADDITIONAL 10' FLEX MC/AC SLACK (COILED); FOR FUTURE DEVICE RELOCATION.DUPLEX RECEPTACLE ON EMERGENCY CIRCUITRECEPTACLE (SINGLE)DOUBLE DUPLEX RECEPTACLE (QUAD) ON NORMAL CIRCUITJJPPDISCONNECT SWITCH - FUSED.MOTOR STARTER.SYMBOLSYMBOL6'-0"6'-0"6'-0"6'-0"30" - 36"CLGCLG, 18"18"18"18"48"48"90"46"46"46"46"90"90"46"46"18"18"90"84"84"84"84"MOUNTINGHEIGHTMOUNTINGHEIGHTMOUNTINGHEIGHT46"46"46"46"HANDHOLEHHFIRE/SMOKE DAMPER; MOUNT PER DWGS.FFPAGING/INTERCOM SPEAKER HORN ASSEMBLY- P.A. OR AS INDICATED (3/4"C. BUSHED EMT TO ACCESSIBLE CEILING). MOUNT 12" BELOW CEILING OR AS INDICATED.FIRE ALARM ANNUNCIATOR PANEL; MOUNT TOP AT 72" AFF.FIREMAN PHONE JACK; MOUNT TOP 54" AFF PLUS OR MINUS 2".SPRINKLER FLOW-SWITCH; MOUNT PER DWGS.SPRINKLER TAMPER-SWITCH; MOUNT PER DWGS.SMOKE DETECTOR-CEILING MOUNTED.DUCT SMOKE DETECTOR; MOUNT PER DWGS.CHLORINE GAS SENSOR; CEILING MOUNTED.GAS SHUT-OFF; MOUNT PER DWGS.POWER POLE (DEVICES AS INDICATED)FIRE ALARM CONTROL PANEL (MASTER); MOUNT TOP 62" AFF PLUS OR MINUS 2".FIRE ALARM MANUAL PULL STATION; MOUNT TOP 46" AFF PLUS OR MINUS 2".FIRE ALARM CONTROL MODULE; MOUNT PER DWGS.FIRE ALARM BELL (WP FOR EXTERIOR MOUNTING).MAGNETIC DOOR HOLD-OPEN (WALL MOUNTED); MOUNT PER DWGS.FIRE ALARM HORN (AUDIBLE), WALL MOUNTED.FIRE ALARM ZONE ADAPTER MODULE; MOUNT PER DWGS.FIRE ALARM INDIVIDUAL ADDRESSABLE MODULE; MOUNT PER DWGS.HEAT DETECTOR (RATE-OF-RISE) - CEILING MOUNTED.HEAT DETECTOR (FIXED TEMPERATURE)- CEILING MOUNTED.EMERGENCY LIGHTING UNIT - TWO HEAD MOUNTING AS INDICATED ON DRAWINGS.KEYED NOTE.OCCUPANCY SENSOR - WALL OR CEILING CELING MOUNTOS# INDICATES TYPE PER OCCUPANCY SENSOR SCHEDULEPHOTOCELL - WALL, CEILING, OR ROOF MOUNTED; SEE DRAWINGS.LOUD SPEAKER HORN ASSEMBLY- PA OR SOUND SYSTEM AS INDICATED; VERIFY MOUNTING HEIGHT.(3/4"C. BUSHED EMT TO ACCESSIBLE CEILING).FEEDER OR EQUIPMENT DRAWING NOTE.LOS#SSVSSTV/VIDEO CAMERA, CLOSED CIRCUIT.(WALL OR CEILING MOUNTED, 3/4"C. BUSHED EMT TO ACCESSIBLE CEILING). CAMERA BY OTHERS.SBCBELL/AUDIBLE DEVICE.(3/4"C. BUSHED EMT TO ACCESSIBLE CEILING).CLOCK OUTLET.(3/4"C. BUSHED EMT TO ACCESSIBLE CEILING).D = DOUBLE FACED -VCALL BACK SWITCH.(1/2"C. BUSHED EMT TO ACCESSIBLE CEILING).VOLUME CONTROL.(1/2"C. BUSHED EMT TO ACCESSIBLE CEILING).AMMAUXILIARY INPUT CONNECTOR.(1/2"C. BUSHED EMT TO ACCESSIBLE CEILING).MICROPHONE OUTLET ( WALL OR CEILLING).(1/2"C. BUSHED EMT TO ACCESSIBLE CEILING).SPEAKER WITH BACKBOX (WALL OR CEILING); VERIFY MOUNTING HEIGHT. PA = SPEAKER FOR P.A. SYSTEM; V = WITH INTEGRAL VOLUME CONTROL KNOB; AV = SPEAKER FOR LOCAL AV SYSTEM; Z# = ZONE NUMBER.(3/4"C. BUSHED EMT TO ACCESSIBLE CEILING). WALL DATA AND COMMUNICATIONS OUTLET:(BUSHED EMT TO ACCESSIBLE CEILING SPACE OR AS INDICATED). ## INDICATES TYPE OF OUTLET. SEE DETAIL SHEETS.DOOR RELEASE; MOUNT PER DWGS.MOTION DETECTOR; ARROW INDICATES DIRECTION.(WALL OR CEILING MOUNTED).ELECTRIC EYE; MOUNT PER DWGS.MASTER CONTROL STATIONKEYPAD; VERIFY MOUNTING HEIGHT WITH DWGS.LOCAL ALARMCARD READER ROUGH-IN AT ADA HEIGHTPHOTO-ELECTRIC RECEIVER; MOUNT PER DWGS.PHOTO-ELECTRIC TRANSMITTER; MOUNT PER DWGS.MDSSMDSSECURITY DEVICE. ## INDICATES THE FOLLOWING:CM CONTROL MODULEDC DOOR CONTACTS (MONITORING)EL ELECTRIC LOCKES ELECTRIC STRIKEGB GLASS BREAK DETECTORIR INFARED DETECTORML MAGNETIC LOCKPT ELECTRIC POWER TRANSFERXP EXIT PUSHBUTTON, MOUNT AT ADA HTXS EXIT SENSORLLHSRECESSED FLUORESCENT LIGHT FIXTURE (TYPE DENOTED)SURFACE MOUNTED FLUORESCENT LIGHT FIXTURE (TYPE DENOTED)LIGHT FIXTURE ON EMERGENCY CIRCUIT, SWITCHEDSECURITY CAMERA, CLOSED CIRCUIT.(WALL OR CEILING MOUNTED, 3/4"C. BUSHED EMT TO ACCESSIBLE CEILING).S SFLUORESCENT STRIP LIGHTING FIXTURE; FOR SUSPENDED MOUNTING HEIGHTS, SEE DRAWINGS.####PT#FB#CONDUIT CONTINUATION12"X4"FLOOR RECEPTACLE (DEVICE TYPE AS INDICATED)FLRFLRSWITCHING NOTATION. ## INDICATES THE FOLLOWING:3 THREE-WAY4 FOUR-WAYD DIMMERK KEYEDLV LOW VOLTAGE, MOMENTARY CONTACTMC MOMENTARY CONTACTOS INTEGRAL OCCUPANCY SENSORPL LIGHTED PILOT LIGHTTD TIME DELAY##RECEPTACLE NOTATION. ## INDICATES THE FOLLOWING:AB ABOVE COUNTER, BOTTOM OF BOX 4" ABOVE BACKSPLASH HHIGH MOUNTED (90")H/L HIGH AND LOW MOUNTED (90" AND 18")IG ISOLATED GROUNDGFI GROUND FAULT CIRCUIT INTERRUPTERTR TAMPER RESISTANTUSB(2) USB PORTS INTEGRAL WITH RECEPTACLEWP WEATHERPROOFUSB ONLY DEVICE, (4) USB CHARGING PORTS 18"CONDUIT SLEEVE WITH BUSHINGS ON BOTH ENDS,SEE SCHEDULE FOR QUANTITIES AND SIZES OF SLEEVESSL#ELEVATION, SEE DETAIL # ON SHEET E#.E##LIGHT FIXTURE ON EMERGENCY CIRCUIT, UNSWITCHEDREMERGENCY LIGHTING RELAY (UL 924) - SEE WIRING SCHEMATIC ON DETAIL SHEETS. Z#JFLR, CLG, 18"FAAPFACPDUPLEX RECEPTACLE ON NORMAL CIRCUIT18"DOUBLE DUPLEX RECEPTACLE (QUAD) ON EMERGENCY CIRCUIT18"AVSCDWAPCEILING DATA OUTLET AND WIRELESS ACCESS POINT:(BUSHED EMT TO ACCESSIBLE CEILING SPACE OR AS INDICATED). ## INDICATES TYPE OF OUTLET. SEE DETAIL SHEETS.##FLOOR DATA AND COMMUNICATIONS OUTLET:(RACEWAY ROUTING AS INDICATED ON PLANS). ## INDICATES TYPE OF OUTLET. SEE DETAIL SHEETS.FLRSURFACE MOUNTED DUPLEX / QUAD RECEPTACLES AND DATA OUTLETS ##RNACFIRE ALARM NOTIFICATION APPLIANCE CIRCUIT PANEL. MOUNT TOP 62" AFF PLUS OR MINUS 2".FFFFFIRE ALARM STROBE (VISUAL) DEVICE - 75 Cd, U.N.O. (WALL OR CEILING MOUNTED).FIRE ALARM HORN/STROBE (COMBINATION) - 75Cd, U.N.O. (WALL OR CEILING MOUNTED). ## INDICATE THE FOLLOWING:WG WIRE GUARDWP WEATHER PROOFVE VOICE EVAC## #### ##A.DEVICES SHALL BE MOUNTD AT THE HEIGHT INDICATED, UNLESS NOTED OTHERWISE. HEIGHTS ARE MEASURED TO FROM DEVICE CENTER TO FINISHED FLOOR. DEVICES MOUNTED IN BLOCK/BRICK WALLS SHALL CORRESPOND WITH BLOCK/BRICK COURSING. SEE MASONRY BACKBOX MOUNTING HEIGHT DETAIL.B.ALL MOUNTING HEIGHTS INDICATED ARE FROM THE FINISH FLOOR TO THE CENTER OF THE BOX.C.D.ON DEMOLITION DRAWINGS, DASHED ELECTRICAL ITEMS DENOTES EXISTING ITEMS TO BE REMOVED; SOLID SCREENED ELECTRICAL ITEMS DENOTES EXISTING ITEMS TO REMAIN, UNLESS NOTED OTHERWISEON NEW WORK LIGHTING, POWER AND SYSTEMS DRAWINGS, SCREENED ELECTRICAL ITEMS DENOTES EXISTING ITEMS TO REMAIN; SOLID ELECTRICAL ITEMS DENOTES NEW ITEMS, UNLESS NOTED OTHERWISEFFDEVICES TO BE DEMOLISHED:EXISING DEVICES TO REMAIN:FNEW DEVICES:46"A. INSTALL CONCEALED CONDUIT WITH FLUSH J.B.'S IN WALLS AND CEILINGS UNLESS NOTED OTHERWISE. IN FINISHED AREAS WITH INACCESSIBLE WALLS OR CEILINGS, PROVIDE SURFACE (WIREMOLD) RACEWAY; PAINT TO MATCH COLOR OF ADJACENT WALL OR CEILING. B. RACEWAYS SHALL CONTAIN A GROUNDING CONDUCTOR.C. CIRCUITS SUPPLYING LINE TO NEUTRAL LOADS SHALL HAVE DEDICATED NEUTRALS, i.e. ONE NEUTRAL PER PHASE. NEUTRAL CONDUCTORS SHALL HAVE TRACER STRIPE ALONG ENTIRE LENGTH INDICATING ASSOCIATED PHASE.D. BUILDING CONDUCTORS SHALL BE THWN/THHN. CONDUCTORS IN UNDERGROUND CONDUIT OUTSIDE OF BUILDINGS SHALL BE XHHW.E. NUMBERS AT RECEPTACLES AND LUMINAIRES CORRESPOND DIRECTLY WITH PANELBOARD CIRCUIT NUMBERS AS SCHEDULED. BRANCH CIRCUIT WIRING AND HOMERUNS ARE NOT SHOWN FOR CLARITY. ACCURATE RECORD DRAWING INFORMATION IS TO BE PROVIDED AT THE PROJECT COMPLETION. TYPICAL THROUGHOUT. REFER TO SPECIFICATIONS FOR MATERIALS AND INSTALLATION REQUIREMENTS.F. REFER TO CONTRACT DOCUMENTS FOR SEQUENCE OF CONSTRUCTION AND PHASING OF THE CONTRACT. G. SWITCHES SHALL BE MOUNTED PER ADA REQUIREMENTS, 46" AFF. UNLESS OTHERWISE NOTED, RECEPTACLES AND TELECOMMUNICATION OUTLETS IN FINISHED AREAS SHALL BE MOUNTED 18" AFF. RECEPTACLES IN UN-FINISHED SPACES SHALL BE MOUNTED AT 48" OR 4" ABOVE WORK SURFACE. COORDINATE RECEPTACLE MOUNTING HEIGHTS WITH MILLWORK LOCATIONS, ARCHITECTURAL ELEVATIONS, AND MASONRY COURSING.H. CRITICAL DEVICES / EQUIPMENT, INCLUDING TELEPHONE, COMPUTER, SECURITY, AND FIRE ALARM, AFFECT ASSOCIATED SYSTEMS BUILDING-WIDE. THESE SYSTEMS MUST REMAIN OPERATIONAL DURING THE CONSTRUCTION. INDIVIDUAL DEVICES MAY BE DISCONNECTED AND/OR RECONNECTED DURING CONSTRUCTION. COORDINATE POWER OUTAGES WITH OWNER. PROVIDE TEMPORARY PANEL(S) AND/OR CIRCUIT(S) AS/IF NECESSARY TO MAINTAIN CONTINUITY. PROTECT FROM PHYSICAL AND DUST DAMAGE. I. THE BUILDING SHALL MAINTAIN POWER THROUGHOUT THE CONSTRUCTION PROCESS. COORDINATE ENERGIZATION OF NEW EQUIPMENT AND THE CORRESPONDING RECONNECTION OF EXISTING AFFECTED ELECTRICAL DISTRIBUTION EQUIPMENT. J. SEE RELATED PLUMBING AND HVAC DRAWINGS FOR LOCATION OF EQUIPMENT REQUIRING ELECTRICAL CONNECTIONS. COORDINATE INTERCONNECTION REQUIREMENTS WITH EQUIPMENT SHOP DRAWINGS.K. WIRING FOR MISCELLANEOUS HVAC DEVICES AND CONTROLLERS SUCH AS DAMPER MOTORS, THERMOSTATS, DUCT SMOKE DETECTORS, FREEZESTATS, DIFFERENTIAL PRESSURE SWITCHES, OCCUPIED AND UNOCCUPIED SELECTOR SWITCHES, ALARM LIGHTS, ETC., NOT SHOWN ON ELECTRICAL DRAWINGS IS DIVISION 23 WORK.L. FIELD VERIFY EXISTING CONDITIONS. DISCREPANCIES BETWEEN THE DRAWING AND ACTUAL FIELD CONDITIONS SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER PRIOR TO BIDS.M. MAINTAIN EXISTING CIRCUIT CONTINUITY ON ALL SYSTEMS ON THE SITE THAT ARE EXISTING TO REMAIN.N. PROVIDE ALL CONDUIT HOMERUNS AS 3/4"C. MIN.O. COORDINATE ALL WORK WITH OTHER CONTRACTORS AND OWNER.P. ALL CUTTING AND PATCHING FOR DIV. 26 WORK SHALL BE UNDER SUPERVISION AND APPROVAL OF ARCHITECT. Q. REMOVE AND/OR REINSTALL ELECTRICAL DEVICES IN ALL AREAS OF WORK AS REQUIRED AND REPLACE ANY ELECTRICAL DEVICES DAMAGED BY WORK. NOT ALL DEVICES MAY BE SHOWN ON DRAWINGS. R. PROVIDE ALL BOXES, FITTINGS, CONDUIT, WIRING, TERMINATIONS, EQUIPMENT, ETC, FOR A COMPLETE INSTALLATION.S. BRANCH 20A CIRCUIT CONDUCTORS SHOULD BE SIZED AS FOLLOWS:GENERAL ELECTRICAL NOTES120V CCT LENGTH 277V CCT LENGTH AWG< 75' < 75' 1275' - 120' 75' - 280' 10120' - 200' 280' - 450' 86> 200' > 450'FEDCBA12345678EMNNorthCheck:Drawn:Date:Comm:License Number:I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensedunder the laws of the State ofScale:Date3/22/2018 10:26:53 AMC:\Users\jshem\Documents\HIGHVIEW MS PARKING REMODEL (CENTRAL) _jshem.rvtAs indicatedCentral: \\Wae-srv-mn.woldae.com\StPaul\ISD621\MS_HIGHVIEW\182058 - PARKING\ELEC\REVIT\HIGHVIEW MSPARKING REMODEL (CENTRAL) .rvtISD #621: MOUNDSVIEW PUBLIC SCHOOLSHIGHVIEW MIDDLESCHOOL 2018PARKINGREMODELE0.00ELECTRICALSYMBOLS ANDABBREVIATIONS4570 VICTORIA ST NSHOREVIEW, MN 551262300 7TH ST NW,NEW BRIGHTON, MN 55112NOT FOR CONSTRUCTIONOWNER REVIEW SETCheckerAuthorXX/XX/2018182058MINNESOTAXX/XX/2018BRADLEY R. JOHANNSEN43936PROFESSIONAL ENGINEERE0.00 ELECTRICAL SYMBOLS AND ABBREVIATIONSE0.01 ELECTRICAL SITE PLAN - EXISTINGE0.02 ELECTRICAL SITE PLAN - NEWE0.03 ELECTRICAL SCHEDULES AND DETAILSRevisionsDescription Date Num
|