My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2018.08.21 PC
NewBrighton
>
Commissions
>
Planning
>
Planning Commission Packets
>
2018
>
2018.08.21 PC
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/2/2019 11:26:00 AM
Creation date
4/2/2019 11:11:06 AM
Metadata
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
51
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
scale:date: 7/27/2018Dr David Ong2350 Palmer DriveNew Brighton, MN 55112TITLE SHEET856 Raymond <br />Saint Paul MN <br />5 5 1 1 4 <br />651.647.6650 <br />Structural Engineer <br />Stroh Engineering <br />1205 W Kuiaha Rd <br />Haiku HI <br />9 6 7 0 8 <br />General Contractor <br />Heritage Construction <br />Andrew Harvala <br />10908 171st Ave NW, <br />Elk River MN <br />5 5 3 3 0 <br />(763) 633-4080 <br /> <br /> REVISIONS <br />#DATE <br />1750 Commerce Court <br />White Bear Lake, MN <br />5 5 1 1 0 <br />(651)748-1100 <br />SILVER LAKE SMILES <br />NEW BRIGHTON, MINNESOTA <br />LAND USE APPLICATION SET <br />DATE: 7/27/2018 <br />GENERAL CONDITIONS: <br />1. CONTRACTOR SHALL BE RESPONSIBLE FOR CHECKING ALL DIMENSTIONS AND CONDITIONS ON THE JOB, <br />FIELD VERIFY ALL DIMENSIONS FOR EXISTING WORK PRIOR TO EXECUTION OF NEW CONTRUCTION AND <br />NOTIFY ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES. <br />2. CONTRACTOR SHALL NOTIFY THE ARCHITECT IMMEDIATELY IF HE CANNOT COMPLY WITH THE WORK <br />CALLED FOR IN THE DRAWINGS. HE SHALL REQUEST CLARIFICATION FROM THE ARCHITECT ON ANY <br />DISCREPANCIES THAT OCCUR BETWEEN THE PLANS, NOTES, SPECIFICATIONS BEFORE STARTING WORK. <br />3. CONTRACTOR SHALL PERFORM DECONSTRUCTION AS REQUIRED TO ACCOMMODATE NEW WORK. ANY <br />DECONSTRUCTION THAT REQUIRES REFINISHING OF DISTURBED SURFACES TO MATCH NEW OR OLD WORK, <br />SHALL BE CONSIDERED PART OF THE CONTRACTOR'S SCOPE OF WORK. <br />4. EXISTING MATERIALS AND ASSEMBLIES ARE TO BE PROTECTED FROM DAMAGE DURING CONSTRUCTION <br />AS REQUIRED. ANY DAMAGE THAT DOES OCCUR SHALL BE BROUGHT TO THE LEVEL OF FINISH AS PART OF <br />THE SCOPE OF CONSTRUCTION WORK. <br />5. ALL WORK PERFORMED BY THE CONTRACTORS SHALL CONFORM TO THE CODE REQUIREMENTS OF THE <br />JOB, WHETHER OR NOT SPECIFIED IN THE DRAWINGS AND SPECIFICATIONS. CONTRACTORS SHALL BE <br />RESPONSIBLE FOR THE INSPECTIONS OF THEIR WORK. <br />6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROPER FIT AND FINISH DUE TO POOR <br />WORKMANSHIP OR DEFECTIVE MATERIAL WHICH OCCUR WITHIN A PERIOD OF 2 YEARS FROM THE <br />SUBSTANTIAL COMPLETION OF THE JOB. <br />7. CONTRACTORS ARE RESPONSIBLE FOR ALL WASTE REMOVAL THAT IS A BYPRODUCT OF THEIR WORK. <br />8. NO CHANGES OR SUBSTITUTIONS TO THE WORK SHALL BE MADE WITHOUT THE APPROVAL OF THE <br />OWNER AND/OR THE ARCHITECT. FAILURE TO OBTAIN THIS APPROVAL SHALL CAUSE THE CONTRACTOR TO <br />ASSUME FULL RESPONSIBILITY FOR THE SUBSEQUENT MODIFICATION OF THE WORK REQUIRED BY THE <br />OWNER OF ANY REGULATORY AUTHORITY. <br />9. THE CONTRACTOR SHALL MAINTIN A FULL SET OF PLANS AND SPECIFICATIONS ON THE JOB SITE FOR USE <br />BY ALL TRADES DURING CONTRUCTION. <br />10. THE ARCHITECT ASSUMES NO RESPONSIBILITY FOR THE CONSTRUCTION MEANS, METHODS, <br />TECHNIQUES, SEQUENCES, OR SAFETY PROCEDURES AND PROGRESS IN CONJUNCTION WITH THE WORK. <br />NO WARRANTIES NOR MERCHANIBILITY OF FITNESS, NOR SPECIFIC USE IS EXPRESSED OR IMPLIED IN THE <br />USE OF THESE PLANS. <br />GENERAL NOTES: <br />1. ALL DIMENSIONS ARE AS FOLLOWS, U.N.O. NEW WORK IS ASSUMED TO ALIGN WITH EXISTING WORK <br />U.N.O. EXISTING CONSTRUCTION: FACE OF EXISTING WORK. EXTERIOR WALLS: TO FACE OF SHEATHING <br />INTERIOR WALLS: TO FACE OF STUDS FOR FRAMING MASONRY: FACE OF MASONRY. <br />2. DO NOT SCALE DRAWINGS. CONTRACTOR SHALL VERIFY DESCREPAINCIES IN DIMENSIONING INTENT W/ <br />ARCHITECT. <br />3. CONTRACTOR IS RESPONSIBLE FOR ALL FLASHINGS, MATERIAL TOLERANCE AND GAPPING ACCORDING <br />TO THE ACCEPTED STANDARD OF PROFESSIONAL CARE, EVEN IF THOSE ITEMS ARE NOT EXPLICITLY SHOWN <br />IN THE PLANS. <br />ABBREVIATIONS <br />ARCH ARCHITECTURE <br />GC GENERAL CONTRACTOR <br />SPEC SPECIFICATION DOCUMENT <br />ALT ALTERNATE <br />TYP TYPICAL <br />NOM NOMINAL <br />MIN MINIMUM <br />DEMO DEMOLITION <br />VIF VERIFY IN FIELD <br />SF SQUARE FEET <br />NTS NOT TO SCALE <br />AFF ABOVE FINISH FLOOR <br />ASF ABOVE SUBFLOOR <br />T/O TOP OF <br />B/O BOTTOM OF <br />EQ EQUAL <br />GWB GYPSUM BOARD <br />HVAC HEATING VENTILATION AIR CONDITIONING <br />HRV HEAT RECOVERY VENTILATOR <br />ERV ENERGY RECOVERY VENTILATOR <br />WH WATER HEATER <br />W/D WASHER / DRYER <br />DW DISHWASHER <br />SD SMOKE DETECTOR <br />CLG CEILING <br />DRAWING INDEX <br />#SHEET NAME <br />G0.0 TITLE SHEET <br />CIVIL <br />C1.0 EXISTING CONDITIONS & REMOVALS PLAN <br />C1.1 EROSION CONTROL PLAN <br />C2.0 SITE PLAN <br />C3.0 GRADING AND DRAINAGE PLAN <br />C4.0 UTILITY PLAN <br />C5.0 DETAILS <br />C5.1 DETAILS <br />L1.0 LANDSCAPE PLAN <br />L1.1 LANDSCAPE DETAILS <br />ARCHITECTURAL <br />A0.1 ARCHITECTURAL SITE PLAN <br />A1.0 FLOOR PLANS <br />A3.0 EXTERIOR ELEVATIONS <br />A3.1 EXTERIOR ELEVATIONS WITH SCREEN AND MATERIALS <br />A3.2 EXTERIOR PERSPECTIVES <br />PLUMBING <br />P.1 PLUMBING & RISER DIAGRAMS SITE PLAN <br />ELECTRICAL <br />E.1 PHOTOMETRIC SITE PLAN <br />CONTACTS <br />OWNER <br />DR DAVID ONG <br />1125 SILVER LAKE ROAD <br />NEW BRIGHTON, MN 55112 <br />PH. 651.356.5424 <br />ARCHITECT <br />ALCHEMY ARCHITECTS <br />856 RAYMOND AVE <br />SAINT PAUL, MN 55114 <br />PH. 651.647.6650 <br />CONTRACTOR <br />HERITAGE CONSTRUCTION <br />PM: ANDREW HARVALA <br />10908 171ST AVE NW <br />ELK RIVER, MN 55330 <br />PH. 763.633.4080 <br />STRUCTURAL <br />STROH ENGINEERING <br />PM: BERNIE STROH, PE <br />1205 W KULAHA RD <br />HALKU, HI 96708 <br />CIVIL <br />SOLUTION BLUE <br />PM: MITCHELL COOKAS <br />444 CEDAR ST <br />SUITE 1005 <br />ST. PAUL, MN 55101 <br />PH. 651.294.0038 <br />MECHANICAL/ELECTRICAL/PLUMBING <br />HALLBERG ENGINEERING <br />PM: LUKE KUSIE, MECHANICAL <br />PM: SCOTT MASON OR DAVE QUIGLEY, ELECTRICAL <br />1750 COMMERCE CT <br />WHITE BEAR LAKE, MN 55110 <br />PH. 651.748.4346 <br />CODE REVIEW PLAN <br />Scale: 1/8" = 1'-0"1 <br />EXIT ACCESS TRAVEL <br />DISTANCE <br />= 79'-6" <br />(2 EXITS REQ) <br />36'-7 5/8" <br />5 <br />9 <br />' <br />- <br />6 <br /> 7 <br />/ <br />8 <br />" <br />15 OCC <br />= 3" REQ. <br />34" PROV. <br />EGRESS REQUIREMENTS <br />OCCUPANT LOAD (TENANT 1) = 15 OCCUPANTS <br />1005.3.2 15 X .2" = 3" REQUIRED <br />TABLE 1014.3 COMMON PATH OF EGRESS TRAVEL = 100' <br />TABLE 1016.2 EXIT ACCESS TRAVEL DISTANCE <br />B/ NO SPRINKLER = 200' <br />TABLE 1021.2(2) STORIES W/ ONE EXIT <br />FIRST STORY/B/49 OCC = 75' MAX <br />1015.2 TWO EXITS - SPACED EQUAL TO NOT LESS THAN <br />1/2 THE LENGTH OF MAX DIAGONAL OF AREA SERVED <br />59'-7" / 2 = 29'-9 1/2" ACTUAL DISTANCE = 36'-7" <br />CODE REVIEW- MN 2015/ IBC 2012 /IECC 2012 <br />NEW BUILD (MULT-TENANT ) <br />TENANT 1 = DENTAL OFFICE <br />TENANT 2 = NOT OCCUPIED <br />OCCUPANCY - BUILDING OCCUPANCY = B <br />CONSTRUCTION TYPE - VB <br />NON-SPRINKLED <br />TABLE 503. BUILDING HEIGHTS AND AREA LIMITATIONS <br />TABULAR = 2 STORIES / 40' / 9,000 SF <br />ACTUAL GROSS BUILDING AREA = 3,168 SF <br />ACTUAL BUILDING FIRE AREA= 2,968 SF <br />ACTUAL BUILDING HEIGHT = 19' <br />ACTUAL STORIES= 1 STORY + MECHANICAL EQUIPMENT PLATFORM <br />FIRE AREA TENANT 1 = 1,774 SF <br />FIRE AREA TENANT 2 = 1,170 <br />505.3 EQUIPMENT PLATFORM <br />LIMITED TO 2/3 AREA OF THE ROOM WITHIN. (1,774 X 2/3 = 1,181 SF) <br />ACTUAL PLATFORM AREA = 388 SF <br />TABLE 508.4 OCCUPANCIES B & (B / F-1 / M / S-1) <br />HAVE NO REQUIRED SEPARATION. <br />TABLE 601 FIRE-RESISTANCE RATING REQUIREMENTS <br />Primary Structural Frame = 0 <br />Bearing Exterior = 0 <br />Bearing Interior = 0 <br />Non-Bearing Interior = 0 <br />Floor Construction = 0 <br />Roof Construction = 0 <br />TABLE 602 FIRE SEPARATION DISTANCE = 10 < X < 30 <br />VB, B = 0 RATING ON EXTERIOR WALLS <br />TABLE 705.8 MAX AREA OF WALL OPENINGS / FIRE SEPARATION <br />TABLE 803.9 INTERIOR FINISHES <br />ROOMS AND ENCLOSED SPACES = CLASS C <br />FIRE EXTINGUISHER - RATING 2-A (ABC)- 1 REQUIRED <br />TABLE 1004.1.2 AREA PER OCCUPANT <br />BUSINESS AREA = 100 SF/ PERSON <br />USABLE SF IN DENTAL OFFICE = 1,536 SF / 100 = 15 OCCUPANTS <br />TABLE 1505.1 MINIMUM ROOF COVERING CLASSIFICATION <br />TYPE VB = CLASS C <br />TABLE 2902.1 PLUMBING REQUIREMENTS <br />15 OCCUPANTS <br />1 TOILET PER 25 = 1 TOILET REQUIRED <br />1 LAV PER 40 = 1 LAV REQUIRED <br />DRINKING FOUNTAIN NOT REQ. FOR OCCUPANCY LESS THAN 50 <br />1 SERVICE SINK NOT REQUIRED FOR 15 OR FEWER OCCUPANTS <br />2902.2 SEPARATE FACILITIES <br />EXCEPTION 2. SEPARATE FACILITIES NOT REQUIRED W/ OCCUPANT <br />LOAD OF 20 OR LESS.
The URL can be used to link to this page
Your browser does not support the video tag.