Laserfiche WebLink
Needs Assessment: Brightwood Hills Clubhouse Pg. 13 <br />Sports Equipment Storage (Rm B3) <br />Damaged duct insulation <br />Option 1: Patch insulation if possible <br />Option 2: Replace insulation and provide some form of protection to avoid future damage <br />Stair (Rm B4/110) <br />See description on Page 7 regarding code compliance and the designation of the local code <br />official relative to egress function of this stair. If deemed necessary for egress, the following items <br />must be addressed: <br />Stair must be widened per 2015 MN Building Code 1009.4 <br />Hand rails must be provided on both sides per 2015 MN Building Code 1009.15 <br />Door B4 must be relocated to provide pull clearance per 2015 MN Accessibility Code <br />Section 404 <br />Door 110A must be relocated to provide proper push clearance per 2015 MN <br />Accessibility Code Section 404 <br />Stoop outside Door 110A needs to be connected to public way per 2015 MN Building <br />Code Section 1027.5 <br />Door 110A threshold needs to be fixed per 2015 MN Building Code Section 1008.1.7 <br />(013) <br />Other issues regarding the stair are as follows: <br />Minor scratches and scuffs (Image 021) <br />Option 1: Paint to match existing <br />Option 2: Paint entire stair area