Laserfiche WebLink
NO PARKINGNO PARKING NO PARKINGNO PARKINGNO PARKINGNO PARKING <br />SENIOR BLDG <br />FFE=917.00 <br />GFE=905.92 <br />FAMILY BLDG <br />FFE=921.50 <br />GFE=910.42  <br /> <br /> <br /> <br /> <br />SEE PULTE PLANS <br />FOR TOWNHOME <br />DEVELOPMENT INFO <br />SEE PULTE PLANS <br />FOR TOWNHOME <br />DEVELOPMENT INFO <br /> <br />INF 3 <br />60" PERFORATED CMP <br />UNDERGROUND <br />INFILTRATION SYSTEM <br />(1189.5 LF TOTAL) <br />TOP OF PIPE=908.62 <br />OUTLET=906.32 <br />INV=903.62 <br />(SEE DETAIL) <br />INF 1 <br />60" PERFORATED CMP <br />UNDERGROUND <br />INFILTRATION SYSTEM <br />(682.5 LF TOTAL) <br />TOP OF PIPE=905.00 <br />OUTLET=902.70 <br />INV=900.00 <br />(SEE DETAIL) <br />CBMH 111 <br />RIM= 914.78 <br />INV= 911.47 E <br />INV=911.27 S <br />CBMH 110 <br />RIM=915.26 <br />SUMP=901.21 <br />INV=907.14 N <br />INV=909.03 S <br />INV=910.54 E <br />INV=904.21 SW <br />NYLOPLAST 123 <br />RIM= 914.80 <br />INV= 909.19 E <br />INV=908.99 W <br />CB 113 <br />RIM= 914.73 <br />INV=910.71 N <br />NYLOPLAST 124 <br />RIM= 914.50 <br />INV= 910.54 E <br />INV=910.54 W <br />STMH 102 <br />RIM= 913.97 <br />INV= 902.40 S <br />INV=902.40 NW <br />STMH 101 <br />RIM= 911.64 <br />INV= 899.97 SE <br />INV=899.97 N <br />STMH 130 <br />RIM=912.69 <br />SUMP=899.37 <br />INV=902.37 S <br />INV=902.37 NE <br />CB 128 <br />RIM=911.51 <br />SUMP=900.17 <br />INV=903.17 E <br />CB 122 <br />RIM= 913.13 <br />INV= 907.72 E <br />INV=907.72 N <br />STMH 100 <br />RIM= 907.08 <br />INV= 897.35 S <br />INV=897.35 NE <br />135 LF 12" STORM <br />@ 1.00% <br />239 LF 15" STORM <br />@ 0.50% <br />99 LF 12" STORM <br />@ 1.57% <br />129 LF 15" STORM <br />@ 0.99% <br />31 LF 12" STORM <br />@ 1.20% <br />103 LF 15" STORM <br />@ 4.00% <br />30 LF 18" STORM <br />@ 4.02% <br />10 LF 24" STORM <br />@ 3.00% <br />87 LF 24" STORM <br />@ 2.80% <br />75 LF 24" STORM <br />@ 3.50% <br />94 LF 24" STORM <br />@ 2.93% <br />TRENCH DRAIN 126 <br />RIM 905.42 <br />INV(E)=904.42 <br />INV(W)=903.92 <br />CONNECT TO EX. <br />STORM MH <br />(FIELD VERIFY EX. <br />INVERT LOCATION <br />& ELEVATION) <br />INV=903.92 <br />INV=902.00 <br />INV=902.70 <br />INV=903.00 <br />INV=894.60 <br />STMH 121 <br />RIM=908.61 <br />SUMP=901.00 <br />INV=906.53 S <br />INV=904.00 E <br />INV=903.00 <br />50 LF 18" STORM <br />@ 2.00% <br />30 LF 12" STORM <br />@ 1.00% <br />NYLOPLAST 125 <br />RIM= 915.60 <br />INV= 910.84 N <br />INV=910.84 W <br />NYLOPLAST 127 <br />RIM= 915.65 <br />INV=912.65 S <br />43 LF 12" STORM <br />@ 4.66% <br />36" ACCESS RISER <br />-TYP (SEE DETAIL) <br />NYLOPLAST 126 <br />RIM= 915.00 <br />INV= 911.44 N <br />INV=911.44 S <br />118 LF 12" STORM <br />@ 1.03% <br />60 LF 12" STORM <br />@ 1.00% <br />78 LF 12" STORM <br />@ 2.15% <br />9 LF 15" STORM <br />@ 2.00% <br />INV=903.00 <br />INV=899.00 <br />NYLOPLAST 208 <br />RIM= 919.00 <br />INV= 913.34 E <br />INV=913.34 W <br />100 LF 15" STORM <br />@ 1.00% <br />NYLOPLAST 207 <br />RIM= 919.50 <br />INV= 914.54 E <br />INV=914.34 W <br />35 LF 12" STORM <br />@ 1.00% <br />NYLOPLAST 206 <br />RIM= 920.99 <br />INV= 914.89 S <br />INV=914.89 W <br />61 LF 12" STORM <br />@ 1.00% <br />NYLOPLAST 205 <br />RIM= 919.50 <br />INV= 915.50 S <br />INV=915.50 N <br />100 LF 12" STORM <br />@ 1.00% <br />NYLOPLAST 204 <br />RIM= 919.50 <br />INV= 916.50 S <br />INV=916.50 N <br />50 LF 12" STORM <br />@ 2.00% <br />CLEANOUT <br />RIM= 920.50 <br />INV=917.50 N <br />60 LF 12" STORM <br />@ 1.00% <br />INV=906.32 <br />STMH 200 <br />RIM= 912.10 <br />INV= 905.73 N <br />INV=905.83 SE <br />INV=903.10 <br />98 LF 12" STORM <br />@ 2.79% <br />35 LF 15" STORM <br />@ 1.00% <br />INV=906.25 <br />CBMH 215 <br />RIM=915.18 <br />SUMP=903.60 <br />INV=906.60 W <br />INV=906.60 N <br />109 LF 15" STORM <br />@ 1.00% <br />CB 214 <br />RIM= 912.49 <br />INV= 907.94 NW <br />INV= 907.69 W <br />INV=907.69 E <br />INV=908.42 <br />48 LF 12" STORM <br />@ 1.00% <br />CB 217 <br />RIM= 914.27 <br />INV= 911.00 W <br />INV=911.00 E <br />88 LF 12" STORM <br />@ 5.00% <br />80 LF 12" STORM <br />@ 10.21% <br />CB 218 <br />RIM= 918.75 <br />INV= 914.75 NE <br />INV=914.75 E <br />TRENCH DRAIN 219 <br />RIM 909.92 <br />INV(W)=908.92 <br />INV(E)=908.42 <br />INSTALL BACKFLOW <br />PREVENTER ON 12" <br />PIPE NW IN CBMH <br />INSTALL BACKFLOW <br />PREVENTER ON 12" <br />PIPE SOUTH IN STMH <br />36" ACCESS RISER <br />-TYP (SEE DETAIL) <br />INF 2 <br />36" PERFORATED CMP <br />UNDERGROUND <br />INFILTRATION SYSTEM <br />(362 LF TOTAL) <br />TOP OF PIPE=903.00 <br />OUTLET=901.00 <br />INV=900.00 <br />(SEE DETAIL) <br />INV=901.00 <br />INV=900.97 <br />STMH 211 <br />RIM= 920.90 <br />INV= 909.70 NE <br />INV=909.70 SW <br />154 LF 15" STORM <br />@ 1.00% <br />NYLOPLAST 210 <br />RIM= 912.92 <br />INV= 911.24 E <br />INV=911.24 SW <br />126 LF 15" STORM <br />@ 1.00% <br />NYLOPLAST 209 <br />RIM= 914.18 <br />INV= 912.50 E <br />INV=912.50 W <br />84 LF 15" STORM <br />@ 1.00% <br />36" ACCESS RISER <br />-TYP (SEE DETAIL) <br />36" ACCESS RISER <br />W/ DRAINAGE <br />GRATE (SEE DETAIL) <br />160 LF 6" DRAINTILE @ 0.00% <br />INV=917.00 <br />INV=906.60 <br />INV=906.60 <br />CB 216 <br />RIM= 914.24 <br />INV= 911.93 W <br />INV=911.93 E <br />30 LF 12" STORM <br />@ 3.07% <br />40 LF 15" STORM <br />@ 1.76% <br />STMH 212 <br />RIM= 911.99 <br />INV= 909.00 NE <br />INV=909.00 SE <br />161 LF 15" STORM <br />@ 0.50% <br />STMH 213 <br />RIM= 912.00 <br />INV= 908.19 NW <br />INV=908.19 E <br />99 LF 15" STORM <br />@ 0.50% <br />18 LF CASING FOR STORM <br />UNDER RETAINING WALL <br />(SEE DETAIL) <br />CLEANOUT <br />RIM= 921.34 <br />INV= 915.91 S <br />INV=915.91 W <br />157 LF 12" STORM <br />@ 1.02% <br />CLEANOUT <br />RIM= 919.84 <br />INV=917.50 N <br />111 LF 12" STORM <br />@ 0.99% <br />CLEANOUT <br />RIM= 921.40 <br />INV= 914.81 W <br />INV= 914.81 E <br />INV=910.42 SW64 LF 12" STORM <br />@ 2.50% <br />109 LF 12" STORM <br />@ 0.99% <br />CLEANOUT <br />RIM= 921.19 <br />INV= 916.42 SW <br />INV=916.42 E <br />CLEANOUT <br />RIM= 921.27 <br />INV=917.50 NE <br />CLEANOUT <br />RIM= 921.23 <br />INV=917.50 SE <br />70 LF 12" STORM <br />@ 7.80% <br />CLEANOUT <br />RIM= 914.84 <br />INV= 912.00 NW <br />INV=912.00 E <br />4 LF 12" STORM <br />@ 2.00% <br />6" PVC W/ <br />12"X6" WYE - TYP. <br />(SEE DETAIL) <br />6" PVC W/ <br />12"X6" WYE - TYP. <br />6" PVC W/ <br />12"X6" WYE - TYP. <br />(SEE DETAIL) <br />6" PVC W/ <br />12"X6" WYE - TYP. <br />(SEE DETAIL) <br />CLEANOUT <br />RIM= 905.67 <br />INV=902.67 E <br />125 LF 12" STORM <br />@ 1.00% <br />CLEANOUT <br />RIM= 908.36 <br />INV= 901.42 W <br />INV=901.42 N <br />45 LF 12" STORM <br />@ 1.00% <br />CLEANOUT <br />RIM= 916.89 <br />INV=913.83 E <br />99 LF 12" STORM <br />@ 1.02% <br />CLEANOUT <br />RIM= 916.68 <br />INV= 912.82 W <br />INV=912.82 N <br />133 LF 12" STORM <br />@ 1.00% <br />CLEANOUT <br />RIM= 916.68 <br />INV= 911.49 S <br />INV= 912.43 N <br />INV=911.29 W <br />13 LF 12" STORM <br />@ 1.00% <br />CLEANOUT <br />RIM= 916.83 <br />INV= 912.56 NW <br />INV=912.56 S <br />37 LF 12" STORM <br />@ 1.00% <br />CLEANOUT <br />RIM= 916.75 <br />INV= 912.93 W <br />INV=912.93 SE <br />44 LF 12" STORM <br />@ 1.00%CLEANOUT <br />RIM= 916.22 <br />INV=913.37 E <br />CLEANOUT <br />RIM= 916.37 <br />INV=913.44 E <br />43 LF 12" STORM <br />@ 1.00% <br />CLEANOUT <br />RIM= 916.74 <br />INV= 913.01 W <br />INV=913.01 NE <br />36 LF 12" STORM <br />@ 1.00% <br />CLEANOUT <br />RIM= 916.75 <br />INV= 912.65 SW <br />INV=912.65 N <br />15 LF 12" STORM <br />@ 1.00% <br />55 LF 12" STORM <br />@ 1.00% <br />CLEANOUT <br />RIM= 916.45 <br />INV= 912.02 N <br />INV= 912.50 S <br />INV=912.02 W <br />60 LF 12" STORM <br />@ 0.99% <br />CLEANOUT <br />RIM= 916.85 <br />INV= 912.61 W <br />INV=912.61 S107 LF 12" STORM <br />@ 1.01% <br />CLEANOUT <br />RIM= 916.61 <br />INV=913.70 E <br />6" PVC W/ <br />12"X6" WYE - TYP. <br />(SEE DETAIL) <br />6" PVC W/ <br />12"X6" WYE - TYP. <br />(SEE DETAIL) <br />6" PVC <br />6" PVC <br />6" PVC W/ <br />12"X6" WYE - TYP. <br />(SEE DETAIL) <br />6" PVC W/ <br />12"X6" WYE - TYP. <br />(SEE DETAIL) <br />12" STORM <br />20' INSULATION BETWEEN <br />BUILDING & STORM SEWER <br />(SEE DETAIL) <br />30' INSULATION BETWEEN <br />BUILDING & STORM SEWER <br />(SEE DETAIL) <br />6" CLEANOUT -TYP <br />(SEE DETAIL) <br />CONVERT STRUCTURE <br />TO HAVE FLAT CASTING <br />IN DRIVEWAY <br />40 LF 6" DRAINTILE <br />@ 5.00% <br />35 LF 6" DRAINTILE <br />@ 5.00% <br />CONNECTION TO <br />TOP OF 60" CMP <br />Architecture <br />Interior Design <br />Landscape Architecture <br />Engineering <br />Boarman <br />Kroos <br />VogelGroupInc. <br />EOE <br />License Number <br />I hereby certify that this plan, specification <br />or report was prepared by me or under my <br />direct supervision and that I am a duly <br />Licensed Professional <br />under the laws of the State of Minnesota.BKVTB-30x42Engineer <br />Date <br />07/30/201924440 <br />Michael J. St. Martin, PE <br />LOUCKS <br />7200 Hemlock Lane, Suite 300 <br />Maple Grove, MN 55369 <br />763.424.5505 <br />www.loucksinc.com <br />PLANNING <br />CIVIL ENGINEERING <br />LAND SURVEYING <br />LANDSCAPE ARCHITECTURE <br />ENVIRONMENTAL <br />LOUCKS PROJECT NO. 18373.00 <br />© 2016 BKV Group, Inc. EOE <br />SHEET NUMBER <br />SHEET TITLE <br />DRAWN BY <br />CHECKED BY <br />COMMISSION NUMBER <br />ISSUE # DATE DESCRIPTION <br />PROJECT TITLE <br />CONSULTANTS <br />NOT F <br />O <br />R <br />CONS <br />T <br />R <br />U <br />C <br />TI <br />O <br />N <br />CERTIFICATION <br />DATE <br />OLD HIGHWAY 8 <br />REDEVELOPMENT <br />18373.00 <br />08/20/2019 <br />AJA <br />SRT <br />OWNER/DEVELOPER <br />02/22/2019 CITY SUBMITTAL <br />03/27/2019 CITY SUBMITTAL <br />04/18/2019 WATERSHED <br />05/31/2019 WATERSHED <br />06/14/2019 PRICING/PERMIT SET DRAFT <br />07/30/2019 PERMIT AND PRICING SET <br />08/20/2019 CITY/WATERSHED <br />N <br />EXISTING UTILITIES. THEY SHALL COOPERATE WITH ALL UTILITY COMPANIES IN <br />THE ABOVE WHEN DAMAGED DURING CONSTRUCTION AT NO COST TO THE <br />STRUCTURES BEFORE DIGGING. THE CONTRACTOR SHALL REPAIR OR REPLACE <br />WIRES, CABLES, CONDUITS, PIPES, MANHOLES, VALVES OR OTHER BURIED <br />THE CONTRACTOR SHALL CONTACT GOPHER STATE ONE CALL AT 651-454-0002 <br />MAINTAINING THEIR SERVICE AND / OR RELOCATION OF LINES. <br />OWNER. <br />THE CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING FOR LOCATIONS OF ALL <br />WARNING: <br />AT LEAST 48 HOURS IN ADVANCE FOR THE LOCATIONS OF ALL UNDERGROUND <br />Gopher State One Call <br /> <br />23 <br />UTILITY NOTES <br />1. ALL SANITARY SEWER, STORM SEWER AND WATERMAIN UTILITIES SHALL BE FURNISHED AND INSTALLED PER THE REQUIREMENTS <br />OF THE SPECIFICATIONS,THE MINNESOTA PLUMBING CODE, THE LOCAL GOVERNING UNIT , AND THE STANDARD UTILITIES <br />SPECIFICATION OF THE CITY ENGINEERS ASSOCIATION OF MINNESOTA (CEAM), LATEST EDITION. <br />2. ALL UTILITY PIPE BEDDING SHALL BE COMPACTED SAND OR FINE GRANULAR MATERIAL. ALL COMPACTION SHALL BE PERFORMED <br />PER THE REQUIREMENTS OF THE CEAM SPECIFICATION. <br />3. ALL CONNECTIONS TO EXISTING UTILITIES SHALL BE PERFORMED PER THE REQUIREMENTS OF THE STATE AND LOCAL <br />JURISDICTIONS. THE CITY DEPARTMENT OF ENGINEERING AND BUILDING INSPECTIONS DEPARTMENT AND THE CONSTRUCTION <br />ENGINEER MUST BE NOTIFIED AT LEAST 48 HOURS PRIOR TO ANY WORK WITHIN THE PUBLIC RIGHT OF WAY, OR WORK <br />IMPACTING PUBLIC UTILITIES. <br />4. ALL STORM SEWER , SANITARY SEWER AND WATER SERVICES SHALL TERMINATE 5' FROM THE BUILDING FACE UNLESS OTHERWISE <br />NOTED. <br />5. A MINIMUM OF 18 INCHES OF VERTICAL SEPARATION AND 10 FEET OF HORIZONTAL SEPARATION IS REQUIRED BETWEEN <br />WATERMAIN AND ALL OTHER UTILITIES UNLESS OTHERWISE NOTED. <br />6. ALL NEW WATERMAIN AND SERVICES MUST HAVE A MINIMUM OF 8.0 FEET OF COVER. EXTRA DEPTH MAY BE REQUIRED TO <br />MAINTAIN A MINIMUM 18" VERTICAL SEPARATION TO SANITARY OR STORM SEWER LINES. THE CONTRACTOR SHALL FIELD ADJUST <br />WATERMAIN TO AVOID CONFLICTS WITH SANITARY SEWER, STORM SEWER, AND SERVICES AS REQUIRED. INSULATION OF WATER <br />AND SANITARY SEWER LINES SHALL BE PROVIDED WHERE 8.0 FEET MINIMUM DEPTH CAN NOT BE ATTAINED. <br />7. ALL FIRE HYDRANTS SHALL BE LOCATED 5 FEET BEHIND BACK OF CURB OR EDGE OF PAVEMENT UNLESS OTHERWISE NOTED. <br />8. ALL SANITARY SEWER WYES, TEES AND SERVICES SHALL BE SCH. 40 PVC. <br />9. ALL PORTIONS OF THE STORM SEWER SYSTEM, INCLUDING CATCH BASINS, LOCATED WITHIN 10 FEET OF THE BUILDING OR WATER <br />SERVICE LINE MUST BE TESTED ACCORDANCE WITH MINNESOTA RULES, PART 4715.2820 <br />10. ALL JOINTS AND CONNECTIONS IN THE STORM SEWER SYSTEM SHALL BE GASTIGHT OR WATERTIGHT (SEE MINNESOTA RULES, PART <br />4715.0700). APPROVED RESILIENT RUBBER JOINTS MUST BE USED TO MAKE WATERTIGHT CONNECTIONS TO MANHOLES, <br />CATCHBASINS, AND OTHER STRUCTURES. <br />11. HIGH-DENSITY POLYETHYLENE (HDPE) STORM DRAINS MUST COMPLY WITH MINNESOTA RULES, PART 4715.0540: <br />a. PIPES 4-INCH TO 10-INCH IN SIZE MUST COMPLY WITH AASHTO M252. <br />b. PIPES 12-INCH TO 60-INCH IN SIZE MUST COMPLY WITH ASTM F2306. <br />c. ALL FITTINGS MUST COMPLY WITH ASTM D3212. <br />d. WATER-TIGHT JOINTS MUST BE USED AT ALL CONNECTIONS INCLUDING STRUCTURES. <br />12. HYDRANT USE: CONTRACTOR IS RESPONSIBLE TO NOTIFY PUBLIC UTILITIES DEPARTMENT WHEN THEY NEED TO USE A HYDRANT; <br />ONLY PRE-AUTHORIZED HYDRANTS WILL BE USED. HYDRANTS TO BE OPERATED ONLY WITH PROPER EQUIPMENT SUCH AS A <br />HYDRANT NUT WRENCH, NOT A PIPE WRENCH, HYDRANT METER IS AVAILABLE FROM PUBLIC UTILITIES DEPARTMENT. ANY TRUCK, <br />ETC. FILLED FROM A HYDRANT MUST BE METERED, MUST HAVE PHYSICAL BREAK OR BACK-FLOW PREVENTER APPROVED BY PUBLIC <br />UTILITIES DEPARTMENT. ALSO APPLIES TO SUBCONTRACTORS. <br />13. OPERATING VALVES FOR TURNING WATER MAIN ON/OFF: PUBLIC UTILITIES DEPARTMENT WILL OPERATE ALL VALVES AND FILL ALL <br />WATER MAINS (PUBLIC AND PRIVATE). CONTRACTOR SHALL GIVE AT LEAST 24 HOURS NOTICE TO HAVE WATER SHUT OFF AND <br />SHALL NOTIFY IN WRITING, ALL AFFECTED CUSTOMERS AT LEAST 24 HOURS IN ADVANCE BEFORE SHUT OFF; ATTACH TO DOOR, <br />ETC., NOT IN MAILBOXES. <br />14. TEMPORARY SERVICE: THE CONTRACTOR SHALL PROVIDE TEMPORARY SERVICE IF SERVICE CANNOT BE RESTORED SAME DAY. IF <br />USING HYDRANT FOR TEMPORARY SERVICE, NOTIFY PUBLIC UTILITIES DEPARTMENT AND USE ONLY PRE-APPROVED HYDRANT AND <br />SUPPLIED HYDRO METER WITH BACK FLOW. THE CONTRACTOR'S TEMPORARY MAIN SHALL BE DISINFECTED, FLUSHED AND <br />BACTERIOLOGICAL ANALYSIS SHOWN NEGATIVE PRIOR TO PUTTING THE TEMPORARY SYSTEM IN SERVICE. THE TEMPORARY WATER <br />SYSTEM SHALL BE IN PLACE PRIOR TO THE PUBLIC UTILITIES DEPARTMENT SHUTTING OFF ANY WATER MAINS. <br />15. ALL PROPOSED STRUCTURES SHALL HAVE FLEX SEAL INSTALLED ON THE ADJUSTING RINGS. <br />16. STORM SEWER MATERIALS: PRIVATE: 12" OR GREATER: HDPE <br /> DOWNSPOUT COLLECTION PIPE: PVC <br />PUBLIC: RCP <br />STORM SEWER <br />PLAN <br />C4-2 <br />SCALE IN FEET <br />0 40 80 <br />CONSTRUCTION LIMITS