Planning Report

 

Date:             June 15, 2004

Case:             NC04-02, LP04-04

Subject:      Non-Conforming Use Permit & Site Plan

Applicant: Faulkner Construction on behalf of Doug DuFresne of Midwest Powder Coating, Inc.

 

 

Request

 

The Planning Commission is asked to hold a public hearing and consider an application by Mr. James Faulkner, Architect, on behalf of Assembly, Packaging, & Screen Printing, for a Nonconforming Use Permit and Site Plan Review. 

 

The purpose of the request is to construct a 14,000 square foot addition onto the existing building at 750 1st Street SW.  The site has the following type 4 non-conformities:

 

1.       The employee parking area does not have curb and gutter on the west side; and encroaches into the front yard setback;  

2.       The existing structure encroaches into the rear yard setback;

3.       The landscaping is dead or missing; and,

4.       Outdoor storage is not screened from the right-of-way.

 

The Zoning Code identifies the above conditions as a Type 4 Nonconforming Use, which requires a public hearing.

 

 

Findings

C         Section 8-010, Site Plan Review  

C         Section 8-460, Regulations as to Type 4 Nonconformities

 

 

Site Characteristics

 

1.     Location:                                      750 1st Street SW       

2.     Lot Size:                                      The site is 75,588 sq. ft. (1.74 acres).

3.     Topography:                                 flat

4.     Vegetation:                                  trees along south side; dead landscaping around perimeter 

5.     Sensitive Areas:                           none

6.     Comprehensive Plan Designation:        HI, Heavy Industrial

7.     Zoning:                                        I-2, Heavy Industrial

8.     Surrounding Land Uses:

               North:                                   Heavy Industrial - Rebarfab, Inc

               South:                                    Heavy Industrial – Armstrong Rigging

               East:                                      Heavy Industrial - Rebarfab, Inc

               West:                                    Modern Press Printing – Light Industrial.    

 

 

 

 

Site History

1.     Past Uses:                                   Midwest Powder Coating printing

2.     Historical Significance:                 None

 

Departmental Considerations

Community Development

1.          Building Setbacks:                       

 

 

Required

Existing

Proposed

Front

40’

40’

40’

Side Street

40’

242

105’

Side

15’

30’

30’

Rear

20’

11

11’

 

The existing building encroaches into the rear yard setback for Industrial lots by 9 feet.

 

 

2.          Parking & Drive Aisle Setbacks:  

 

 

Required

Existing

Proposed

Front

40’

10

40’

Side Street

40’

115’

40’

Side

5’

5’

5’

Rear

5’

12’

12’

 

The applicant has a shared parking and access agreement with the adjacent property owner to the east, Rebarfab, Inc.  The City has a signed letter by the President and CEO, Mr. James Belland.

 

The parking lot has two nonconformities: an existing encroachment into the front yard setback; and, curbing on the east side of the lot is missing.  The proposal is to remove the encroaching spaces within the front yard setback and landscape the area.  Also, the applicant is proposing to pull existing parking within the required setback on the west side.

 

3.     Parking Spaces Required:            1 per 350 sq. ft or 1 per employee on a major shift.

                                                            20 employees

        Proposed Parking:                       41 stalls.

 

 

4.     Parking Spaces Proposed:           15 stalls existing

                                                           Future parking area is proposed to extend west from and can provide an additional 26 stalls.       

 

        Existing lot to the west is partially paved; new stalls are proposed to be paved and

 

The proposed lot eliminates the parking surface non-conformity

 

 

 

5.     Handicap Parking:                       Required: 1 Stall        Existing: 0 Stalls                 

 

Not shown on plan.  Building permit submittal should show ADA compatible stall.

 

 

6.     Stall Size:                                     9 x 18 (complies)  

7.     Drive Aisle Size (two way):          Required: 24 feet        Proposed: 24 feet

8.     Total Drive Entrances:                  One (1) - Off of Old Highway 8

9.     Driveway Width:                          Maximum:  36 feet     Existing: 30 feet

Proposed: 30 feet.

 

The applicant will need to apply with the Department of Public Works for a curb cut permit for the new west side driveway onto 1st Street SW.

 

10.   Concrete Curbing:                       missing along east lot line

11.   Parking Area Surface:                  mixed; bituminous with a large dirt/gravel areas.

12.   Landscaping/Screening:                The applicant is proposing to plant 4 snow mound crab trees and 5 hydrangea specimens along the south lot line along 1st Street SW

                                                           At time of writing, I have not spoken to the City Forester about the submitted plans

 

13.   Impact on Land Uses:                        None

 

 

Public Works

1.     Streets:                                        Street and utilities off of 1st Street SW. 

2.     Curb Cuts:                                   One new curb cut proposed

                                                           This will require a curb cut permit from the City

 

3.     Utilities:                                       Existing    

4.     Grading/Drainage:                        New parking lot to drain south toward 1st Street SW.  City engineering staff find this to be acceptable.

5.     Rice Creek Watershed District:    applied for.

6.     Environmental Concerns:              None

7.     Other Considerations:                  None

 

Building Official

1.     Structure Size:                             Existing:             13,264 square feet

                                                           Proposed:          14,000 square ft. addition (27,264 total)

2.     Structure Height (allowed):           40 feet

3.     Structure Height (proposed):        21 feet (complies).

4.     Exterior Treatment:                      Painted concrete block and panel - to match the existing building

Fire

1.     Hydrant Locations:                      South across street

2.     Access to Site:                             Adequate

3.     Access to Structure:                     Adequate

4.     Other Considerations:                  None

 

 

Staff Comments

 

 

Type 4 nonconforming use permit

 

The purpose of the request is to construct an addition onto the existing building.  The list below is the existing non-conformities:

 

1.      The employee parking area does not have curb and gutter on the west side; and encroaches into the front yard setback; 

2.      The existing structure encroaches into the rear yard setback;

3.      The landscaping is dead or missing; and,

4.      Outdoor storage is not screened from the right-of-way.

 

 

 

 

1.       Parking setbacks and materials 

 

The existing parking does not meet the required forty (40) foot front yard setback and much of the west lot is dirt or gravel.  The applicant is proposing to expand, pave, and provide curb and gutter around a new parking area in the west yard (8th Ave SW)

 

The new parking area conforms to yard setback requirements. 

 

 

 

2.       The existing structure encroaches into the rear yard setback

 

The existing building encroaches 9 feet into the rear yard.  The applicant’s production lines maximize the internal space.  The applicant believes conforming to the building setback is not reasonable and not feasible.

 

This non-conformity will remain with the property

 

 

 

3.       The landscaping is dead or missing

 

The existing trees along the south side of the building are alive.  There does not seem to be any landscaping along the west side adjacent to the 8th Ave SW right-of-way.  The site plan states “new sod and plantings” near the boulevard to 8th Avenue. 

 

Although the submitted landscape plans will be better than the existing conditions, the applicant should detail “plantings” for the west side and submit them to Staff.

 

 

4.       Outdoor storage is not screened from the right-of-way.

The new addition will have additional inside storage and therefore remove this non-conformity. 

 

                        This non-conformity is satisfied

 

 

 

 

 

Sec. 8-460. Regulations.

 

The Council may grant permission only if one or more of the following conditions are met:

A. The total number of nonconformities is reduced.

B. The impact of any nonconformity upon adjacent premises is reduced to the greatest practical extent.

C. The extent of any nonconformity is reduced where practical.

 

The applicant’s site plan reduces the number of nonconformities by the addition of a paved parking area with curb and gutter, improving the landscaping, and removing the unscreened, outdoor storage.  These improvements will greatly improve the overall image of the site.

 

The proposed site plan meets the regulations for Type 4 Nonconformi­ties of Section 8-460

 

 

 

Staff Recommendation

Staff recommends approval of the non-conforming use permit and site plan subject to the conditions outlined below.

 

Approval

Motion to waive the reading and adopt the attached resolution recommending approval of the Non-conforming Use Permit and Site Plan NC-02-02 and LP04-04 subject to the following conditions:

 

1.      Review by and compliance with Rice Creek Watershed District.

2.      A drawing for the west elevation is submitted and approved by the City Planner.

3.      A permit is applied for and approved by the City Engineer for the new curb cut.

4.      An ADA parking stall is added and drafted on submitted building permit plans. 

5.      Landscape plans are re-submitted to be approved by the City Planner.

 

 

 

 

 

 

Patrick Boylan

City Planner