Laserfiche WebLink
Floor Area Ratio <br /> (Zoning Code Section 5-250) Proposed <br /> Not to exceed 1.0 <br /> (3,365 SF addition+7,590 SF existing= 10,955 SF total 0.2 <br /> building/66,070 SF of land area) <br /> The proposed F.A.R is well within the maximum allowed in the B-3 zoning district. <br /> Parking Setbacks Required Proposed <br /> (Zoning Code Section 11-020) <br /> Front 30' 30' <br /> Side (west boundary) 5' 5' <br /> Rear 25' 25' <br /> It's worth noting the property does not have direct access onto County Road D West. Rather, the <br /> applicant has shared access across the commercial uses adjacent and shared access to Old <br /> Highway 8 SW across the multi-family property to the northeast. All required parking setbacks <br /> are met. The Zoning Code Section 11-040(7) allows for exemptions to meeting the required <br /> parking setbacks when shared facilities are present. In this case, only the actual driveway <br /> providing access to the site crosses the property line. <br /> Required # of Parking Stalls Required Proposed <br /> (Zoning Code Section 11-030) (based on 90%of gross floor SF) <br /> 3,365 SF Addition 15 - <br /> Existing 7,590 SF Clinic 34 - <br /> Total= 10,955 49 48 <br /> Based on the above analysis, the proposed Site Plan provides one less parking stall than the <br /> minimum required under Zoning Code Section 11-030(3). The applicant is requesting approval <br /> of an "other use or unique circumstance" as allowed in Zoning Code Section 11-040(4). Zoning <br /> Code Section 11-030 only provides a parking ratio for clinic and office, but not specifically <br /> dental clinic. In this case it seems reasonable to consider an "other use or unique circumstance", <br /> as long as the applicant has provided sufficient evidence to support the amount of parking that is <br /> proposed. Based on the information supplied in the applicant's narrative, staff would support <br /> construction of 48 parking stalls, one less than the minimum required using the professional <br /> office building parking ratio of 1 stall/200 SF. <br /> Landscaping <br /> The Landscape Plan approved in January remains unchanged, other than relocation of two <br /> canopy trees and elimination of two shrubs near where the proposed addition will be located. <br /> Both the tree and shrub requirements of Section 8-010 are based on a ratio of total building <br /> square footage or site perimeter, whichever is greater. This site is large enough the site perimeter <br /> standard is applied to determine minimum landscaping requirements. Thus, with the <br /> introduction of additional building square footage, the landscaping requirements remain <br /> unchanged. <br /> Nonetheless, the applicant has provided a supplemental Landscaping Plan illustrating <br /> landscaping details near the proposed addition. The applicant is proposing 10 additional shrubs, <br />