Laserfiche WebLink
Q U O T E <br />JSKRQ2288-01 <br />Created: 11/20/19 <br />Expires: 01/07/20 <br />T. 651-227-8461 F. 651-310-12961 Water St West, Suite 110, St Paul, Minnesota 55107 <br />Prepared For:Prepared By: <br />City of New Brighton <br />803 Old Higway 8 NW <br />New Brighton MN 55112 <br />John Jantzer <br />Account Representative <br />651-310-1257 <br />jjantzer@electrowatchman.com <br />Nick Kriz <br />(612) 618-2375 <br />Nick.Kriz@newbrightonmn.gov <br />Project Scope: <br />Electro Watchman to provide and install Avigilon ACM access control upgrades to existing city buildings with <br />existing access control equipment. <br />*Estimate assumes existing electric door hardware is viable and in proper working order unless otherwise <br />mentioned. Reconnect existing field door hardware. Owner responsible for faults in existing system design <br />discovered during installation. <br />*All access control equipment requires a wired data network connected to main system control server located at <br />Public Safety building for operation. Owner responsible for providing data network infrastructure and connection <br />for each field controller. <br />*Some locations have a proprietary cabling/controller design which will need to be converted to industry standard <br />configuration prior to reconnection to new system. See individual building descriptions for specific locations of <br />concern. <br />*New building access controller equipment will be installed at each location based on current controller locations <br />and overall design. New controllers include electric door lock power outputs for each door location. <br />Main Server Requirements: <br />*Initial system installation at Public Safety building included a 32 reader license. To allow system expansion to the <br />total doors estimated, a license update must be purchased and installed to allow a total of 80 reader locations. <br />City Hall Options: <br />*Upgrade/Replace 1 existing controller with 14 door connections in upper level data closet. Several doors appear <br />to have been installed with non-industry standard cabling and must be rerouted. <br />*Three existing request to exit (REX) motion detectors are black and will be replaced with white. <br />*Reconnect all door locations. <br />*Recable lower level tenant card reader key switch bypass as an input in the access control system rather than <br />preventing reader from operating when activated. <br />*Reconnect Council Chamber maglock emergency release buttons. <br />Maintenance Facility Options: <br />*Upgrade/Replace 1 existing controller with 8 door connections located in storage room. Install a controller with <br />expansion capability beyond 8 door locations. All doors appear to have been installed with non-industry standard <br />cabling and must be recabled. <br />*Recable to all door locations. An extension lift will require access through the garage bay spaces to recable to <br />existing door locations. <br />*Reconnect all field door hardware. <br />*Main gate for property currently has 2 card readers connected as single port on the access control system. <br />Existing cabling connection to the building could not be found in walk-through. Option has been provided to <br />recable new underground pathway from gate/card reader pedestal to building for connection to new system. Gate <br />recabling cannot be completed by subcontractor until ground has thawed in 2020 or will require additional expense.