My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
LP-104
NewBrighton
>
Commissions
>
Commissions-OLD
>
PLANNING
>
Planning
>
Site Plan File - Approved PLZ 01900
>
LP-101-200
>
LP-104
>
LP-104
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/25/2008 9:46:15 AM
Creation date
11/14/2006 3:36:40 PM
Metadata
Fields
Template:
House File
PIN Number
323023120017
Address
720 1ST ST SW
House Number
0720
Street
1ST
Street Type
ST
Direction
SW
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
32
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />NC-47, LP-I04 <br />Page 2 <br /> <br />The required two (2) handicap parking spaces should be <br />designated. In addition, there is a chain link security <br />fence that should have slats to provide the necessary <br />screening. In general, the site has a large amount of <br />parts, materials and debris piled in a number of locations. <br />The materials should be placed within the building or <br />stored in an orderly fashion. <br /> <br />BUILDING PERMIT APPLICATION, LP-I04 <br /> <br />There are a number of revisions that must be <br />plans: <br /> <br />Thi s addi tion \ <br />Uniform BUilding) <br />of the proposa~ <br /> <br />made to the <br /> <br />; <br />(The site plan depicts an open shed addition. <br />is not allowed under the restrictions in the <br />Code. The applicant has withdrawn this part <br /> <br />1. The southern-most parking space on the site plan <br />extends into the front yard and will therefore have <br />to be removed; <br />2. The site plan must provide for 80 parking spaces, <br />two (2) spaces for handicapped parking. There <br />appears to be adequate space on the site for the <br />additional spaces; <br />3. The proposed shed should be removed from the plans; and <br />4. Outside storage areas should be noted as to size and <br />materiai to be storedo <br /> <br />The exterior treatment of the small addition will match <br />the existing building. It should be noted that in addition <br />to the decorative block a small amount of standard concrete <br />block will be used. This is an expansion of a Type IV <br />non-conformity "and requires the approval of a non-conforming <br />use variance. The non-conforming use variance is warranted <br />on the basis that the addition is very small in size and <br />only a very small percentage of the exterior wall treatment <br />will be standard concrete block. <br /> <br />STAFF RECOMMENDATION <br /> <br />Staff recommends that NC-47 be recommended for approval <br />by waiving the reading and adopting the attached resolution. <br /> <br />Staff further recommends that" LP-I04 be recommended for <br />approval subject to the following conditions: <br /> <br />1. That final grading and drainage plans be approved <br />by the Rice Creek Watershed District and City Engineer; <br />2. That the plans be revised to depict the following: <br />A. 80 parking spaces including two (2) handicap spaces; <br />B. Removal of the southern-most parking space; <br />C. Removal of proposed shed; and <br />D. Outside storage areas and materialso <br /> <br /> <br />1}1~ - tk. 6- () <br />
The URL can be used to link to this page
Your browser does not support the video tag.