My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
LP-298
NewBrighton
>
Commissions
>
Commissions-OLD
>
PLANNING
>
Planning
>
Site Plan File - Approved PLZ 01900
>
LP-201-299
>
LP-298
>
LP-298
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/18/2007 1:08:57 AM
Creation date
1/5/2007 1:08:47 PM
Metadata
Fields
Template:
House File
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
171
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />FIRE <br /> <br />1 . Hydrant locations: <br />2. Other Considerations: <br /> <br />POLICE <br /> <br />1 . Accident Counts: <br />2. Violations: <br />3. Other Considerations: <br /> <br />Page 3 <br /> <br />One on 6th Avenue NW <br />None <br /> <br />None of record <br />None of record <br />None <br /> <br />DEPARTMENTAL CONSIDERATIONS (PROPOSED USE) <br /> <br />COMMUNITY DEVELOPMENT <br /> <br />1. Proposed Use: <br /> <br />2. lot Size: <br />3. Density/FAR: Building: <br /> Allowed: <br /> Proposed: <br />4. Building Setbacks: <br />5. Parking Setbacks: <br />6. Total Parking: <br />7. Stall Size: <br />8. Aisle Size: <br />9. Total Drives: <br />10. Drive Size: <br />11. Concrete Curbing: <br />12. Parking Area Surface: <br />13. Truck Bays: <br />14. Dock Area: <br />15. Exterior Storage: <br />16. landscaping/Screening: <br />17. Performance Standards: <br />18. Impact on <br /> Surrounding land Uses: <br />19. Other Considerations: <br /> <br />The applicant proposes to construct a canopy over two new <br />gasoline pump islands on the subject site. The existing parking <br />lot would be expanded and improved and a new walk area <br />constructed around the existing building. <br />48, 767 square feet or 1.1 acres <br />50' x 80' or 4,000 s.f. + 1,392 s.f. canopy = 5,392 s.f. <br />structure <br />75% <br />11 % <br /> <br />Existing building complies <br />Proposed canopy: Complies except for front setback would <br />be 24 feet from the front property line. <br />Existing parking lot is setback six feet from front property line <br />at one point and has no setback from rear property line. <br />Required: 17 stalls <br />Proposed: 1 7 stalls <br />9' x 18' <br />24 feet <br />Two drives - one new/one existing. The existing westerly <br />drive would be closed. <br />36 feet and 26 feet, respectively <br />To be installed <br />Bituminous <br />None <br />None <br />None <br />The existing Pyramidal Arborvitae on the boulevard would be <br />removed and replaced with shrubs and flowers. Additional <br />deciduous trees would be planted along boulevard area. <br />Complies <br /> <br />Minimal <br />None <br />
The URL can be used to link to this page
Your browser does not support the video tag.