My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
LP-328
NewBrighton
>
Commissions
>
Commissions-OLD
>
PLANNING
>
Planning
>
Site Plan File - Approved PLZ 01900
>
LP-300-399
>
LP-328
>
LP-328
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/25/2007 2:54:10 PM
Creation date
1/18/2007 4:24:45 PM
Metadata
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
76
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DEPARTMENTAL CONSIDERATIONS (PROPOSED USE) <br />COMMUNITY DEVELOPMENT <br />2. <br />3. <br />4. <br />5 <br />6. <br />7. <br />8. <br />9. <br />10. <br />11. <br />12. <br />13. <br />14. <br />Proposed Use: The applicant proposes to construct two additions to the west <br /> side of the existing building. <br />Lot Size: 746,135 S.F. <br />Density/FAR: Allowed: 40% Proposed: 23% <br />Building and Parking Setbacks: The proposed drive around the west side of the building would <br /> be setback 60 feet from the west property line or adjacent R-1 <br /> district. The final addition to the Remmele plant would be <br /> located 100 feet from said property line. Both setbacks would <br /> comply with the I-3 district standards. <br />Total Parking: Required: 426 Stalls / Proposed: 248 Existing Stalls <br /> 178 Proof of Parking Stalls <br /> 426 Total Parking Stalls <br />Stall Size: <br />Aisle Size: <br />Total Drives: <br />Drive Size: <br />Concrete Curbing: <br />Parking Area Surface: <br />Landscaping/Screening: <br />Impact on Surrounding Land Uses: <br />Other Considerations: <br />PUBLIC WORKS <br />1. Streets: <br />2. Curb Cuts: <br />3. Utilities: <br />4. Easements: <br />5. Grading/Drainage: <br />6. Rice Creek Watershed District: <br />7. Environmental Concerns: <br />8. MPCA: <br />9. Other Considerations: <br />BUILDING <br />Structure Size: <br />2. Structure Height: <br />3. Exterior Treatment: <br />4. Other Considerations: <br />9ft.x18ft. <br />24 ft. <br />two, they remain the same size and location <br />32 ft. <br />Provided <br />Bituminous <br />Existing <br />Minimal <br />None <br />None <br />None <br />Connected <br />Drainage Easement <br />None <br />Waiting for permit approval <br />None <br />NA <br />None <br />Existing building - 111,413 sq. ft. <br />First addition - 21,740 sq. ft. <br />Second addition - 32,610 sq. ft. <br />Total expansion - 54,350 sq. ft. <br />34 ft. <br />Precast concrete panels <br />None <br />G:\CD\-97-PC\-97-RPTS\LP-328. WPD
The URL can be used to link to this page
Your browser does not support the video tag.