My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2017.05.16 Planning
NewBrighton
>
Commissions
>
Planning
>
Planning Commission Packets
>
2017
>
2017.05.16 Planning
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/11/2018 11:41:18 AM
Creation date
1/11/2018 11:25:00 AM
Metadata
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
115
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
A single user, TUV SUD will occupy the site. <br /> <br />(6) Architectural styling shall not be the sole basis for denial of a planned unit development. <br /> <br />Staff finds the architectural styling to be compatible with the surrounding area and with several <br />of the following architectural guidelines of the NWQ Framework Plan, which was adopted in <br />2005 in advance of the NBE, New Brighton Exchange zoning district: <br />• Building Placement – while not directly at the corner, attention is paid to orient the <br />building to follow the frontages of 14th ST NW and Northwest Parkway. <br />• Expressive Front Entry – the applicant has created a larger glass expanse at the NW <br />corner of the building near the front entry as well as a prominent blue feature wall that <br />runs perpendicular to the façade. <br />• Interior Courtyard – the applicant has included an outdoor plaza area at the NW corner <br />of the building, adding a pedestrian presence to the exterior of the site. <br /> <br />(7) The maximum gross floor area for the sum of all buildings in a project shall not exceed 45 <br />percent of the total land area in the planned unit development. For purposes of determining <br />compliance with this provision, the first two aboveground floors of structures used exclusively <br />for parking of vehicles shall not be included as part of the gross floor area of the development. <br />Subject to approval of the City Council, the gross floor area may be increased for any new <br />Planned Unit Development that is located in the area known as the Northwest Quadrant project <br />area, as defined by the Northwest Quadrant Framework Plan approved by the City Council. <br /> <br />This standard is met. The proposed gross floor area is 20% (36,500 SF of building area / <br />182,477 SF of lot area). When including the future expansion space of 12,200 SF, the F.A.R. <br />would consist of 27%, well below the 45% maximum established under this standard. <br /> <br />(8) All buildings shall observe the following setbacks unless otherwise specified by the Council <br />at the time of approval of the planned unit development: <br /> <br />A. There shall be a minimum setback of the height of the building, or thirty feet, whichever <br />is greater, from all property lines that form the perimeter of the entire plan of the planned <br />unit development. Subject to approval of the City Council, building setbacks may be <br />decreased from the perimeter setback requirement for any new Planned Unit <br />Development if pedestrian linkages to neighboring developments for residents, <br />employees, or shoppers are provided along with an approved streetscape plan with <br />enhanced landscaping. <br /> <br />This standard is met. The building is approximately 38’ in height and the shortest <br />perimeter setback of the building is to the southwest at 34’. This section allows <br />reductions from the minimum setback, in this case 38’, when pedestrian linkages to <br />neighboring developments and an enhanced landscape plan are included. In an effort to <br />comply with the exception, the applicant has provided sidewalk connections along 14th ST <br />NW to Old Highway 8 NW and east to Northwest Parkway, providing pedestrian linkages <br />to neighboring developments – both north/south and east/west. The applicant has also <br />provided an enhanced landscape plan. Staff finds this reasonable based on the intent of <br />the PUD and the originally adopted principles of the Northwest Quadrant Framework <br />Plan. <br />
The URL can be used to link to this page
Your browser does not support the video tag.