My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2018.08.28 CC
NewBrighton
>
Council
>
Packets
>
2018
>
2018.08.28 CC
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/14/2019 3:22:02 PM
Creation date
2/14/2019 1:59:29 PM
Metadata
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
79
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Minor Subdivision, SUP, and Site Plan Review; Silver Lake Smile <br />City Council Report; 8-28-18 <br /> <br /> <br />Page 9 <br /> Lot Access: Lot access points from Palmer Drive will not change. The existing curb cut to the <br />west of The Garage will be used by the proposed building. <br /> The proposed entry into the BP property to the west will shift to the north from its <br />present location. Provided the proper easements are in place with the neighboring <br />property, staff sees no issue with this minor change. <br /> As a condition of approval, the City Attorney shall review all easement <br />documentation to ensure ingress/egress rights are fully executed. <br /> As a condition of approval, all Engineering comments on the memo dated 8/7/18 <br />shall be addressed. <br /> <br />Water <br />System(s): <br /> As a condition of approval, the following Engineering comments (also on the <br />memo dated 8/7/18) shall be addressed: <br />1. City watermain runs along the West property line (not shown on plans), the <br />City will require a 10’ easement. Add watermain and easement to plans. Water <br />service needs to come off this line vs. an open cut in Palmer Drive. Fire <br />Marshall and Mechanical Contractor to determine sizing and specific <br />requirements for fire protection if required. Depending on size of service <br />needed for fire flow, a separate domestic line may be required. <br />2. A permit will be required for all sewer and water connections and shall be <br />inspected by Public Works. <br />3. The owner/engineer will need to obtain a permit from MnDOLI for watermain <br />construction and internal plumbing design. <br />4. A curb stop or gate valve will be required to allow for service shut-offs. <br /> <br />Sanitary <br />System(s): <br /> As a condition of approval, the following Engineering comments (also on the <br />memo dated 8/7/18) shall be addressed: <br />1. Outside City, sewer and water permit is required for sanitary and water service <br />connections. <br />2. An existing service stub was provided for this lot. It is located at 201 feet west <br />of the downstream MH. The length and condition of the stub is unknown. Plans <br />should use this location for sewer connection and if re-use is desired, line must <br />be televised to verify condition of pipe. Plans for saw cutting Palmer Dr <br />pavement and sidewalk should be updated to this location. Replacement of <br />these materials should be equal to or greater than the existing sections. <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.