Laserfiche WebLink
8. Add elevations to proposed contours. <br /> <br />9. Add note about exposing block and lowering footing along Building Addition 1. Elevation details of <br />this building do not match grading plan (see sheet A3 details 7-8 vs. C1.31). <br /> <br />10. Need a removals plan. <br /> <br />11. More detail is needed for existing building and proposed fill where it connects to Building Addition <br />1, was building designed to support fill against (or will waterproofing/other methods be required to <br />allow for it). <br /> <br />12. Detail 5 C2.11 shows draintile around addition, but none is shown on plan. Please advise. <br /> <br />13. Adjust grading limits to cover utility corridors, possibly move silt fence. <br /> <br />14. New Storm MH in street to be Flex-sealed. <br /> <br /> <br />Watermain <br /> <br />1. The watermain system within the site is to be considered private and shall be constructed and <br />maintained by the property owners. A permit will be required for all sewer and water connections <br />and shall be inspected by Public Works. Show fire department connection. <br /> <br />2. The owner/engineer will need to obtain a permit from MnDOLI for watermain construction and <br />internal plumbing design. <br /> <br /> <br />Sanitary Sewer <br /> <br />1. The sanitary sewer services are to be considered private and shall be constructed and <br />maintained by the property owners. A permit will be required for all sewer and water connections <br />and shall be inspected by Public Works. <br /> <br />2. New San MH in street to be Flex-sealed. <br /> <br />